Get ABEND S000 U0C15-000E FOI524E CONNECT FAILED. RC=12, RSN=212 IVP009E - CONNECT FUNCTION FAILED when using SFRXSAMP(FRXIVPT1) JCL.
Local fix
By adding IMS reslib to the IVP //STEPLIB after tools loadlib you will be able to connect.
Problem summary
**************************************************************** * USERS AFFECTED: ALL TOSI USERS * **************************************************************** * PROBLEM DESCRIPTION: TOSI IVP job fails because TOSI fails * * to register with SCI. The registration * * fails because IMS RESLIB in ot in the * * IVP job //STEPLIB * **************************************************************** * RECOMMENDATION: * **************************************************************** FOICIVP0 is modified not to register with SCI when IMS type-1 command is requested.
Problem conclusion
Fixed.
Temporary fix
Comments
APAR Information
APAR number
PM39120
Reported component name
IMS TOOLS BASE
Reported component ID
5655V9300
Reported release
110
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-05-12
Closed date
2011-05-31
Last modified date
2011-06-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK68307
Modules/Macros
FOICIVP0
Fix information
Fixed component name
IMS TOOLS BASE
Fixed component ID
5655V9300
Applicable component levels
R110 PSY UK68307
UP11/06/01 P F105
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCJN3E","label":"IBM Tools Base"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0"}]
Document Information
Modified date:
19 October 2020