A fix is available
APAR status
Closed as program error.
Error description
QMF V10 does not support 24 positive and negative time zone for TIMESTAMP WITH TIME ZONE data type
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All QMF for TSO/CICS V10 users. * **************************************************************** * PROBLEM DESCRIPTION: QMF does not accept the full 24:00 * * time zone range for the * * TIMESTAMP WITH TIME ZONE data type. * **************************************************************** * RECOMMENDATION: * **************************************************************** The range of time zones accepted for activity involving the TIMESTAMP WITH TIME ZONE data type was limited to +14:00 and -12:29, instead of 24:00.
Problem conclusion
Code has been amended to accept time zone ranges of 24:00 for the TIMESTAMP WITH TIME ZONE data type.
Temporary fix
Comments
APAR Information
APAR number
PM37101
Reported component name
QMF-QUERY MGMT
Reported component ID
566872101
Reported release
A10
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-04-14
Closed date
2011-06-10
Last modified date
2011-07-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK68673
Modules/Macros
DSQCFIDC DSQCFIIR DSQCFIVR DSQGDRCI DSQGDRVI DSQIISQL DSQPNLE DXEDVR DXYEHIB1 DXYE1040 DXYE1227 DXYE1228 DXYE1872 DXYE2308 DXYE2466 DXYE2473 DXYE2474 DXYE2475 DXYE2476 DXYE2477 DXYE2478 DXYE2479 DXYE2480 DXYE2481 DXYE2482
Fix information
Fixed component name
QMF-QUERY MGMT
Fixed component ID
566872101
Applicable component levels
RA10 PSY UK68673
UP11/06/14 P F106
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCWRCK","label":"QMF for TSO\/CICS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.1.0","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: