A fix is available
APAR status
Closed as program error.
Error description
- IMS PI attempts to validate UNIT values for logs as specified in the RECON dataset by checking against output from the EDTINFO call on the system on which IMS PI is running. This system may not be the same system as the system on which the RECON entries were created. There is no requirement to perform this check if CAT=YES is specified in the ALZPARM dataset. - For log record 67D0 subtype 02 we got: MSGALZ0051E Log Record formatting failed; Code=67D0 LSN=00000000001B7D8C KM=ALZ67D0C Reason=01 Field=D02SRDC
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: IMS PI users of DBRC log selection with * * RECON datasets created on a different * * system. * **************************************************************** * PROBLEM DESCRIPTION: ALZ0542E xxxx Log data set has * * unsupported UNIT type, * * DSN=datasetname * **************************************************************** * RECOMMENDATION: * **************************************************************** IMS PI attempts to validate UNIT values for logs as specified in the RECON dataset by checking against output from the EDTINFO call on the system which IMS PI is running. This system may not be the same system as the systam on which the RECON entries were created. There is no requirement to perform this check if CAT=YES is specified in the ALZPARM dataset.
Problem conclusion
When CAT=YES is specified bypass UNIT validation. Note: Additional changes to update Knowledge Modules for X'07', x'0A07', x'4507' and x'56FA' included to support IMS changes.
Temporary fix
Comments
APAR Information
APAR number
PM36785
Reported component name
IMS PROBLEM INV
Reported component ID
5655K5000
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-04-12
Closed date
2011-06-22
Last modified date
2011-07-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK69020
Modules/Macros
ALZA0A19 ALZA0A29 ALZA0A39 ALZA0A49 ALZA0A69 ALZA0419 ALZA0429 ALZDBRCJ ALZTRACK ALZTUTRK ALZ0A07A ALZ0A07B ALZ0A07C ALZ0A077 ALZ0A078 ALZ0A079 ALZ0A08A ALZ0A08B ALZ0A08C ALZ0A087 ALZ0A088 ALZ0A089 ALZ0B01S ALZ01A ALZ01B ALZ01C ALZ017 ALZ018 ALZ019 ALZ07A ALZ07B ALZ07C ALZ0701S ALZ0702S ALZ077 ALZ078 ALZ079 ALZ31A ALZ31B ALZ31C ALZ317 ALZ318 ALZ319 ALZ32A ALZ32B ALZ32C ALZ327 ALZ328 ALZ329 ALZ35A ALZ35B ALZ35C ALZ357 ALZ358 ALZ359 ALZ37A ALZ37B ALZ37C ALZ377 ALZ378 ALZ379 ALZ38A ALZ38B ALZ38C ALZ387 ALZ388 ALZ389 ALZ4507A ALZ4507B ALZ4507C ALZ45077 ALZ45078 ALZ45079 ALZ55A ALZ55B ALZ55C ALZ557 ALZ558 ALZ559 ALZ67D0A ALZ67D0B ALZ67D0C ALZ67D07 ALZ67D08 ALZ67D09 ALZ6701A ALZ6701B ALZ6701C ALZ67017 ALZ67018 ALZ67019
Fix information
Fixed component name
IMS PROBLEM INV
Fixed component ID
5655K5000
Applicable component levels
R220 PSY UK69020
UP11/06/25 P F106
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A4","label":"IMS Problem Investigator"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
05 July 2011