A fix is available
APAR status
Closed as program error.
Error description
When HD Pointer Checker (HDPC) processed a HDAM or PHDAM database, MSGFABP3664E was issued erroneously although there was no error in the database.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: IBM IMS High Performance Pointer Checker for * * z/OS Version 3 Release 1 (FMID=HPC2310) * * users who run HD Pointer Checker(HDPC). * **************************************************************** * PROBLEM DESCRIPTION: When HDPC processed a HDAM or PHDAM * * database, MSGFABP3664E was issued * * erroneously although there was no error * * in the database. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** HDPC issues MSGFABP3664E erroneously under the following conditions: - HDPC processes a HDAM database data set of the data set group 1 or a PHDAM database data set of the data set group ID A. - The maximum size of the space where segments can be stored in one CI or block allocated in the root addressable area (RAA) is less than the longest segment size defined in the DBD. - The number of the allocated CIs or blocks is less than the number of the CIs or blocks in the RAA.
Problem conclusion
The following modules have been changed to fix the errors: FABPHPSD FABPHSDA FABPPSDA FABPSDA0
Temporary fix
Comments
APAR Information
APAR number
PM36355
Reported component name
IMS POINTER CHE
Reported component ID
5655E0900
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-04-05
Closed date
2011-04-21
Last modified date
2011-05-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK67015
Modules/Macros
FABPHPSD FABPHSDA FABPPSDA FABPSDA0
Fix information
Fixed component name
IMS POINTER CHE
Fixed component ID
5655E0900
Applicable component levels
R310 PSY UK67015
UP11/04/23 P F104
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89G","label":"IMS HP Pointer Checker"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0"}]
Document Information
Modified date:
04 October 2020