A fix is available
APAR status
Closed as program error.
Error description
The average CPU time computed in the SMF 120.x records was computed as type long but, using divison by an int. This causes a loss of percision which can be significant.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of WebSphere Application Server * * V7.0 * **************************************************************** * PROBLEM DESCRIPTION: Average CPU time in SMF 120 subtype 6 * * and SMF 120 subtype 8 interval records * * are not accurate. * **************************************************************** * RECOMMENDATION: * **************************************************************** Average CPU time (SM120JMQ) in SMF 120 subtype 6 interval records is not accurate. Average CPU time (SM120WJ4) in SMF 120 subtype 8 interval records is not accurate. SM120JMQ and SM120WJ4 are not accurate because the code is keeping a running average using integer addition and division. Losing the remainder each time the running average is recalculated causes the average CPU time to be inaccurate.
Problem conclusion
Changed the code to keep the total cpu time and divide once when the record is written. APAR PM36288 is currently targeted for inclusion in Service Level (Fix Pack) 7.0.0.19 of WebSphere Application Server V7.0. Please refer to URL: //www.ibm.com/support/docview.wss?rs=404&uid=swg27006970 for Fix Pack availability.
Temporary fix
Comments
APAR Information
APAR number
PM36288
Reported component name
WEBSPHERE FOR Z
Reported component ID
5655I3500
Reported release
700
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-04-05
Closed date
2011-06-14
Last modified date
2011-10-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBSPHERE FOR Z
Fixed component ID
5655I3500
Applicable component levels
R700 PSY UK71280
UP11/09/10 P F109
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS7K4U","label":"WebSphere Application Server for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]