A fix is available
APAR status
-
Closed as program error.
Error description
-
When running a batch program with LIU Integrity Checker, LIU Integrity Checker caused ABEND S0C4 because although LIU Integrity Checker tried to refer the IMS version in the loaded IMS module (DFSBSCD0), the module had been deleted.
Local fix
-
N/A
Problem summary
-
**************************************************************** * USERS AFFECTED: IMS Library Integrity Utilities for z/OS, * * Version 2 Release 1 (FMID=H27P210) users * * who use Integrity Checker. * **************************************************************** * PROBLEM DESCRIPTION: Integrity Checker gets ABEND0C4 in the * * FABLRTS0 module in a batch program. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** When running a batch program with Integrity Checker, Integrity Checker caused ABEND0C4 because although Integrity Checker tried to refer the IMS version in the loaded IMS module(DFSBSCD0), the module had been deleted.
Problem conclusion
-
Integrity Checker has been changed to load the IMS module(DFSVC000) and refer the IMS version when running a batch program with Integrity Checker.
Temporary fix
Comments
APAR Information
-
APAR number
PM35070
-
Reported component name
IMS LIBR INTEG
-
Reported component ID
5655I4200
-
Reported release
210
-
Status
CLOSED PER
-
PE
NoPE
-
HIPER
NoHIPER
-
Special Attention
NoSpecatt / Xsystem
-
Submitted date
2011-03-18
-
Closed date
2011-05-04
-
Last modified date
2011-06-02
-
APAR is sysrouted FROM one or more of the following:
-
APAR is sysrouted TO one or more of the following:
UK67533
Modules/Macros
-
FABLRTS0
Fix information
-
Fixed component name
IMS LIBR INTEG
-
Fixed component ID
5655I4200
Applicable component levels
-
R210 PSY UK67533
UP11/05/10 P F105
Fix is available
-
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89N","label":"IMS Library Integrity Utilities"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0"}]
Document Information
Modified date: