IBM Support

PM34612: Invalid Lock Request-Data already Locked Error while trying to change properties of a restored project

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When a Project with an empty Folder is restored in to a DOORS
    Database, any attempt to change the properties of the project
    will lead to an error 'Invalid lock Request- Data already
    locked' error.
    
    This can be reproduced only with projects with an empty folder
    within them. For example , issue can be reproduced with
    
    Project 1
           -? Folder 1
    
    Cannot be Reproduced with
        Project 1
              -? Folder 1
                               -? Module 1
    
    Also can be reproduced with
    
    Project 1
          -? Folder 1
          -? Folder 2
                       -? Module 2
    
    
    There are no locks visible in manage locks or through DBAdmin.
    
    The issue is no longer seen if the user opens the restored
    project and navigates through the empty folders (opening the
    empty folders) , or when the DOORS client is restarted.
    
    This issue is also reproducible in DOORS 8.3
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When a Project is restored in to a DOORS Database, any
    attempt to change the properties of the project will lead to
    an error 'Invalid lock Request- Data already locked' error.
    
    This error existed both in presence and absence of empty
    folders.
    

Problem conclusion

  • To prevent this problem, proper unlocking has been
    implemented.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM34612

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    920

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-03-11

  • Closed date

    2011-09-28

  • Last modified date

    2011-09-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R920 PSN

       UP