IBM Support

PM34292: MSGASN0011E RC00C90064 WHEN DATA PROPAGATOR CAPTURE IS USED ON A TARGET SYSTEM AFTER CLONING TOOL HAS COPIED COMPRESSED TS.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Cloning Tool resets PGLOGRBA to zero in all dictionary page(s).
    When Data Propagator is used on the target system after Cloning
    Tool has copied tablespace(s) which are compressed, the
    following message appears...ASN0011E CAPTURE "ASN" :
    "WorkerThread". The Capture program log read failed because the
    DB2 compression dictionary that was used to create the
    compressed log record no longer exists.  The log record that
    could not be read was for the registered source table xxx.yyyy.
    The reason code is 00C90064.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Cloning Tool.                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: Cloning Tool resets PGLOGRBA to zero in *
    *                      all dictionary page(s). When Data       *
    *                      Propagator is used on the target        *
    *                      system after Cloning Tool has copied    *
    *                      tablespace(s) which are compressed,     *
    *                      the following message appears...        *
    *                      ASN0011E CAPTURE "ASN" :                *
    *                      "WorkerThread". The Capture program     *
    *                      log read failed because the DB2         *
    *                      compression dictionary that was used    *
    *                      to create the compressed log record no  *
    *                      longer exists.  The log record that     *
    *                      could not be read was for the           *
    *                      registered source table xxx.yyyy.       *
    *                      The reason code is 00C90064.            *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM34292

  • Reported component name

    DB2 CLONING TOO

  • Reported component ID

    5655N1000

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-03-07

  • Closed date

    2011-04-01

  • Last modified date

    2011-05-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK66407

Modules/Macros

  • CKZ00501
    CKZ00762
    CKZ00763
    CKZ00764
    

Fix information

  • Fixed component name

    DB2 CLONING TOO

  • Fixed component ID

    5655N1000

Applicable component levels

  • R220 PSY UK66407

       UP11/04/07 P F104

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUUE","label":"IBM Db2 Cloning Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: