PM32537: Compiler error when SpaStatusBytePosition specified and is great than 0

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • User is generating a Cobol program for IMSVS.
    The Build Descriptor option SpaStatusBytePosition is specified
    and is greater than 0.
    
    The generated Cobol program fails compile with a message similar
    to the following:
    
    IGYPS2048-S An invalid abbreviated relation condition was found.
     The statement was
                            discarded.
    
    IGYPS2170-E An object of a simple condition was found after a
    condition name or
                            outside the scope of an abbreviated
    condition.  The object was processed
                            as written but may have unpredictable
    results.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    A space was missing in the code template when spa byte
    position was specified, which caused a compiler error.
    

Problem conclusion

  • Software updated. Fixtest available.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM32537

  • Reported component name

    RBD EGL FOR COB

  • Reported component ID

    5724S5001

  • Reported release

    750

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-02-11

  • Closed date

    2011-05-06

  • Last modified date

    2011-05-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RBD EGL FOR COB

  • Fixed component ID

    5724S5001

Applicable component levels

  • R750 PSN

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]