A fix is available
APAR status
Closed as program error.
Error description
HDCE needs sample JCL for all functions. Right now to bypass the use of the ISPF interface it is necessary to cut and paste from the manual to create JCL. Please provide JCL members in samplib to create a dictionary, to link the driver and dictionary, image copy and unload extracts, Analyze and Examine.
Local fix
Copy JCL from User's Guide
Problem summary
**************************************************************** * USERS AFFECTED: All HSDCE users. * **************************************************************** * PROBLEM DESCRIPTION: No sample JCL jobstreams are provided * * with HDCE. * **************************************************************** * RECOMMENDATION: * **************************************************************** No sample jobstreams are available with HDCE. Users have to copy and paste samples from the Users Guide.
Problem conclusion
The following members were added to the HDCE SHCOSAMP file. HCOJOB1A - ANALYZE SEGMENT DATA WITH IMAGE COPY EXTRACT HCOJOB1B - ANALYZE SEGMENT DATA HCOJOB2A - ANALYZE DATABASE DATA WITH IMAGE COPY EXTRACT HCOJOB2B - ANALYZE DATABASE DATA HCOJOB3A - BUILD A COMPRESSION EXIT WITH IMAGE COPY EXTRACT HCOJOB3B - BUILD A COMPRESSION EXIT HCOJOB4A - EXAMINE AN EXISTING DICTIONARY USING AN IMAGE COPY FILE AS INPUT HCOJOB4B - EXAMINE AN EXISTING DICTIONARY using a HD UNLOAD AS INPUT HCOJOB4C - EXAMINE AN EXISTING DICTIONARY using any other FILE OTHER THAN AN IMAGE COPY FILE OR A HD UNLOAD FILE AS INPUT HCOJOB5A - COMPRESS A FULL FUNCTION DATABASE USING RELOAD HCOJOB5B - COMPRESS A FASTPATH DATABASE USING RELOAD These new samples need to be documented in the Users Guide as an appendix or table.
Temporary fix
Comments
APAR Information
APAR number
PM32347
Reported component name
IMS TOOLS BASE
Reported component ID
5655V9300
Reported release
110
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-02-10
Closed date
2011-06-02
Last modified date
2011-07-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK68416
Modules/Macros
HCOJOB1A HCOJOB1B HCOJOB2A HCOJOB2B HCOJOB3A HCOJOB3B HCOJOB4A HCOJOB4B HCOJOB4C HCOJOB5A HCOJOB5B
| SC19289600 |
Fix information
Fixed component name
IMS TOOLS BASE
Fixed component ID
5655V9300
Applicable component levels
R110 PSY UK68416
UP11/06/06 P F106
Fix is available