IBM Support

PM31574: ZOSBATCH program fails with abend 0C1 if LECOMPLIANT=YES

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • This problem happens when a Cobol file is generated for ZOSBATCH
    by Rational Business Developer 7.5.1.6 and earlier releases,
    with build descriptor user symparm set to LECOMPLIANT=YES.
    
    The led file generated when LECOMPLIANT=YES is specified is in
    error.
    The module is created without error, but the program fails with
    abend 0C1.
    
    
    For example, the generated file is:
    
     INCLUDE OBJLIB(B9LAPLEC)
     CHANGE ELAAPPL(B9LAPLEC)
     INCLUDE SELALMD(ELARLEMN)
     INCLUDE SELALMD(ELARMAIN)
     INCLUDE SELALMD(ELARSINT)
     ENTRY ELARLEMN
    
    
     NAME B9LAPLEC(R)
    
    To be correct, the INCLUDE SELALMD(ELARMAIN) statement must be
    immediately following the CHANGE statement.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The link edit deck had the include statement for ELARLEMN in
    the wrong order. It needed to be moved above the CHANGE
    statement, which allows the change statement to work
    correctly against the WXTRN in the ELARMAIN module.
    

Problem conclusion

  • Software updated. Fixtest available.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM31574

  • Reported component name

    RBD EGL FOR COB

  • Reported component ID

    5724S5001

  • Reported release

    751

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-01-31

  • Closed date

    2011-05-06

  • Last modified date

    2011-05-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RBD EGL FOR COB

  • Fixed component ID

    5724S5001

Applicable component levels

  • R751 PSN

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: