IBM Support

PM30742: LOG ANALYSIS TOOL MAY NOT REPORT ON CERTAIN OBJECTS AFTER THE DB2 LOG RBA HAS BEEN RESET

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Log Analysis Tool uses the table create RBA as stored in
    SYSTABLES field RBA1 in non-data sharing regions to determine if
    the current object in the DB2 catalog is valid for the object
    found in the DB2 log. If the create RBA is greater than the RBA
    of the activity in the log, then Log Analysis Tool reports the
    object as *UNKNOWN because it may or may not be the same object
    as in the catalog. Once the DB2 log RBA aproaches the maximum
    value and is reset - it becomes possible for the object create
    RBA is to be a greater value than the activity RBA. This APAR
    will now change the product to use the object create timestamp
    for the non datasharing region and compare to the LRSN of the
    activity.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Log Analysis Tool.              *
    ****************************************************************
    * PROBLEM DESCRIPTION: Log Analysis Tool uses the table        *
    *                      create RBA as stored in SYSTABLES       *
    *                      field RBA1 in non-data sharing regions  *
    *                      to determine if the current object in   *
    *                      the DB2 catalog is valid for the object *
    *                      found in the DB2 log. If the create RBA *
    *                      is greater than the RBA of the activity *
    *                      in the log, then Log Analysis Tool      *
    *                      reports the object as *UNKNOWN because  *
    *                      it may or may not be the same object as *
    *                      in the catalog. Once the DB2 log RBA    *
    *                      aproaches the maximum value and is      *
    *                      reset - it becomes possible for the     *
    *                      object create RBA is to be a greater    *
    *                      value than the activity RBA. This APAR  *
    *                      will now change the product to use      *
    *                      the object create timestamp for the     *
    *                      non datasharing region and compare to   *
    *                      the LRSN of the activity.               *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • Apply the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM30742

  • Reported component name

    DB2 LOG ANALYSI

  • Reported component ID

    5655E6601

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2011-01-18

  • Closed date

    2011-02-24

  • Last modified date

    2011-04-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK65190 UK65191

Modules/Macros

  •    ALABSDS  ALACDF1  ALAGEN1  ALALF1A  ALAPGR
    ALAREC   ALASQL0  ALASQL7  ALASQL8  ALASQL8C ALASQL9  ALASQL9C
    

Fix information

  • Fixed component name

    DB2 LOG ANALYSI

  • Fixed component ID

    5655E6601

Applicable component levels

  • R310 PSY UK65190

       UP11/03/02 P F103

  • R320 PSY UK65191

       UP11/03/02 P F103

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"320"}]

Document Information

Modified date: