A fix is available
APAR status
Closed as program error.
Error description
DB2 ended but Omegamon did not check for it. Just prior to the SVC DUMP this message was issued: IEF404I DBICMSTR - ENDED Dump Title: OMEGAMON II FOR DB2: COMPID=5655OPE00, JOB=OMD2COL , LMOD=KO2OCNTB#L, CSECT=O2OPCN , OFFSET=0005D2 ABEND0D5-21 KO2OPCNB+5D2 (at PK82532 level) on a B2250010 (SSAR) instruction. R1 contained the ASID of DBICMSTR that just ended. KO2OPCNB was handling a CALL to a routine needing the SECONDARY ASN of DBICMSTR set, but Omegamon neglected to check if that DB2 subsystem was still active. Since it was not active, Omegamon ABENDed. abend0d5 rc21
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - Classic Interface * **************************************************************** * PROBLEM DESCRIPTION: ABENDS0D5 IN KO2OPCNB+5D2 * * * **************************************************************** * RECOMMENDATION: Apply this PTF * * * **************************************************************** PROBLEM SUMMARY: ABEND0D5 occurs when stopping the DB2 MSTR address space. PROBLEM CONCLUSION: Check DB2 stopping ASCB(Address space control block) to prevent an abend.
Problem conclusion
Check DB2 stopping ASCB(Address space control block) to prevent an abend. KEYWORDS : ABENDS0D5 KO2OPCNB+5D2 DB2 MSTR ADDRESS SPACE
Temporary fix
Comments
APAR Information
APAR number
PM29767
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-01-04
Closed date
2011-02-21
Last modified date
2017-02-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK65066 UK65067 UK65068
Modules/Macros
KO2OPCNB
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R410 PSY UK65066
UP11/02/24 P F102
R420 PSY UK65067
UP11/02/24 P F102
R510 PSY UK65068
UP11/02/24 P F102
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
04 February 2017