Error description
IMS HP LOAD WILL NOT STORE REPORTS IN THE ITKB REPOSITORY WHEN RECON1 IS SPARE STATUS WITH ITKB APAR PM26787 The reason is HP Load uses RECON_TYPE=DDN instead of RECON_TYPE=RCN to reference the RECON
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM IMS High Performance Load * * for z/OS Version 2 Release 1 (FMID=H1IM210). * **************************************************************** * PROBLEM DESCRIPTION: HP Load fails to store reports in * * ITKB repository when RECON1 is not * * COPY1 and RECONs are allocated * * dynamically. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** When the status of RECON1 data set is not COPY1 and RECON data sets are allocated dynamically, HP Load fails to store reports in ITKB repository, and issues MSGHPSR0312W. To resolve the problem, APAR PM26787 also needs to be applied to IBM IMS Tools Knowledge Base for z/OS, Version 1 Release 1 (FMID=HAHN110).
Problem conclusion
HP Load has been modified to give correct parameters for ITKB initialization.
Temporary fix
Comments
APAR Information
APAR number
PM26861
Reported component name
IMS HIGH PERF L
Reported component ID
5655E0700
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-11-16
Closed date
2010-11-18
Last modified date
2010-12-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK62285
Modules/Macros
HPSRHALA HPSRHALB HPSRHALM HPSRHAL7 HPSRHAL8 HPSRHAL9 HPSRHDLA HPSRHDLB HPSRHDLD HPSRHDL7 HPSRHDL8 HPSRHDL9 HPSRIT10
Fix information
Fixed component name
IMS HIGH PERF L
Fixed component ID
5655E0700
Applicable component levels
R210 PSY UK62285