A fix is available
APAR status
-
Closed as program error.
Error description
-
HD Pointer Checker(HDPC) gets ABEND0C7 in the multiple-step HASH Check under HPIC when HDPC processes HALDB with the DBDEFCTL data set created by a previous version of IMS HP Pointer Checker V3.1.
Local fix
-
N/A
Problem summary
-
**************************************************************** * USERS AFFECTED: IBM IMS High Performance Pointer Checker for * * z/OS Version 3 Release 1 (FMID=HPC2310) * * users who run the multiple-step HASH check * * under IBM IMS High performance Image copy * * (HPIC). * **************************************************************** * PROBLEM DESCRIPTION: HD Pointer Checker (HDPC) gets ABEND0C7 * * in the Image Copy function of the * * multiple-step HASH check under HPIC * * when HDPC processes HALDB or HISAM DB * * with the DBDEFCTL data set created by a * * previous version of HP Pointer Checker * * V3.1. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** HDPC gets ABEND0C7 in the Image Copy function of the multiple-step HASH check when all of the following conditions are satisfied: - The DBDEFCTL data set that was created by a previous version of HP Pointer Checker V3.1 is used. - HALDB or HISAM DB is processed.
Problem conclusion
-
The FABPGET1 module is modified to fix the error.
Temporary fix
Comments
APAR Information
-
APAR number
PM26513
-
Reported component name
IMS POINTER CHE
-
Reported component ID
5655E0900
-
Reported release
310
-
Status
CLOSED PER
-
PE
NoPE
-
HIPER
NoHIPER
-
Special Attention
NoSpecatt / Xsystem
-
Submitted date
2010-11-11
-
Closed date
2010-11-24
-
Last modified date
2010-12-02
-
APAR is sysrouted FROM one or more of the following:
-
APAR is sysrouted TO one or more of the following:
UK62547
Modules/Macros
-
FABPGET1
Fix information
-
Fixed component name
IMS POINTER CHE
-
Fixed component ID
5655E0900
Applicable component levels
-
R310 PSY UK62547
UP10/11/28 P F011
Fix is available
-
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.