A fix is available
APAR status
Closed as program error.
Error description
One IC has incorrect device catalog information when taking dual copies.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Image Copy for z/OS * * Version 4 Release 1 users ( FMID=H1J0410 ) * **************************************************************** * PROBLEM DESCRIPTION: HP Image Copy ends normally but the * * primary output image copy data set is * * cataloged with the incorrect device * * type when all of the following * * conditions are satisfied: * * - Image Copy function or Create Image * * copy function is processed. * * - The SATCK= keyword is specified in * * the ICEIN control statement. * * - The secondary output image copy is * * requested. * * - The device type of the primary output * * image copy data set is different from * * the one of the secondary output image * * copy data set. * * * * Therefore Recovery function or Create * * Image Copy function will fail to * * dynamically allocate the input image * * copy data sets by using the incorrect * * catalog information. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** HP Image Copy ends normally but the primary output image copy data set is cataloged with the incorrect device type when all of the following conditions are satisfied: - Image Copy function or Create Image copy function is processed. - The SATCK= keyword is specified in the ICEIN control statement. - The secondary output image copy is requested. - The device type of the primary output image copy data set is different from the one of the secondary output image copy data set. Therefore Recovery function or Create Image Copy function will fail to dynamically allocate the input image copy data sets by using the incorrect catalog information. The cause of the problem is that HP Image Copy uses the device type of the secondary image copy data set as the device type for the primary image copy data set at catalog time, so that the device type in the catalog for the primary image copy data set is incorrect.
Problem conclusion
FABJDOPN and FABJCRC1 have been modified to use the correct device type for the CATALOG macro.
Temporary fix
Comments
APAR Information
APAR number
PM26483
Reported component name
IMS HP IMAGE CO
Reported component ID
5655K9600
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2010-11-11
Closed date
2010-11-30
Last modified date
2010-12-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK62646
Modules/Macros
FABJCRC1 FABJDOPN
Fix information
Fixed component name
IMS HP IMAGE CO
Fixed component ID
5655K9600
Applicable component levels
R410 PSY UK62646