  • Closed as program error.

Error description

  • CRVAP0087E CCRC command 'checkin' failed:
    Error:'java.io.IOException: Unable to set last modified time on
    '?Path to file?': Unknown error..'
    
    The above error is seen when the user has a preop checkin
    trigger that performs a modification and the preference
    'Preserve version creation time when files are updated or loaded
    from the server' is enable.
    
    Workaround: Disable CCRC preference 'Preserve version creation
    time when files are updated or loaded from the server'
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    CRVAP0087E CCRC command 'checkin' failed:
    Error:"java.io.IOException: Unable to set last modified time
    on "?Path to file?": Unknown error.."
    
    The above error is seen when the user has a preop checkin
    trigger that performs a modification and the preference
    "Preserve version creation time when files are updated or
    loaded from the server" is enable.
    
    Workaround: Disable CCRC preference "Preserve version
    creation time when files are updated or loaded from the
    server"
    

Problem conclusion

  • A fix is available in ClearCase versions 7.1.1.9, 7.1.2.6
    and 8.0.0.2
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM26027

  • Reported component name

    CLEARCASE WIN

  • Reported component ID

    5724G2900

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-11-05

  • Closed date

    2012-04-05

  • Last modified date

    2012-04-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CLEARCASE WIN

  • Fixed component ID

    5724G2900

Applicable component levels

  • R710 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSSH27","label":"Rational ClearCase"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Edition":"","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]

Document Information

Modified date:
05 April 2012