A fix is available
APAR status
Closed as unreproducible in next release.
Error description
SQL storage cell pool exhausted Additional symptom: KO2O1421E NEAR-TERM HISTORY DATA COLLECTOR - WORKLOAD DANALYZE HAD LOOPED MORE THAN TEN TIMES. TERMINATING (SERVLOOP) KO2O1313W NEAR-TERM HISTORY DATA COLLECTOR SUSPENDED DATA COLLECTION. NO AVAILABLE STORAGE DB2=DBP3 (DASQLOUT) KO2O1314I NEAR-TERM HISTORY DATA COLLECTOR RESUMED DATA COLLECTION. STORAGE AVAILABLE DB2=DBP3 (DASQLOUT) ... check PM23999 HIGH CPU
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - Classic Interface * **************************************************************** * PROBLEM DESCRIPTION: SQL STORAGE CELL POOL EXHAUSTED. * **************************************************************** * RECOMMENDATION: Apply this PTF * * * **************************************************************** PROBLEM SUMMARY: LONG-RUNNING THREADS ARE EXECUTING MANY THOUSANDS OF TRANSACTIONS AND GENERATING VERY HIGH VOLUMES OF SQL DATA. PROBLEM CONCLUSION: THE LIMIT OF THE SIZE FOR SQL ROW CELL POOL IS INCREASED.
Problem conclusion
Temporary fix
Comments
THE LIMIT OF THE SIZE FOR SQL ROW CELL POOL IS INCREASED. KEYWORDS: INCORROUT KO2O1313W KO2O1314I
APAR Information
APAR number
PM23999
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
420
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2010-10-06
Closed date
2010-12-06
Last modified date
2017-02-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK62803
Modules/Macros
KO2HDTPB
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R420 PSY UK62803
UP10/12/08 P F012
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"420","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"420","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: