IBM Support

PM23240: RELOAD JOB TO AN IMPROPER DATA BASE FORMAT SHOULD FAIL INSTEAD OF ENDING WITH RC=00

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • An UNLOAD job had both the IMSACB and NEWACB DD's pointing
    to the same origin ACBLIB by mistake. When attempting to
    reload the database to another IMS, that job ended with a RC=00
    but the format of the data base is not correct, so the
    application cannot get to the data. The database could be opened
    and an analyzer runs fine against it, but the application
    cannot access the data. Therefore a RELOAD job to an improper
    database format should fail, instead of getting a return code
    zero.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of High Performance Fast Path      *
    *                 Utilities Fast Path Advanced Tool Version 3  *
    *                 Release 2 (FMID: H31A320).                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: FPA RELOAD function ended with RC=00,   *
    *                      although the format of the data base    *
    *                      is not correct.                         *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    An unload job had both the IMSACB and NEWACB DDs pointing to
    the same origin ACBLIB by mistake. When attempting to reload
    the database to another IMS, that reload job ended with RC=00,
    but the format of the reloaded data base is not correct, because
    the IMSACB that is specified for the reload job is inconsistent
    with the NEWACB that is specified for the UNLOAD job. Then,
    the application cannot get to the data.
    

Problem conclusion

  • This APAR enables FPA UNLOAD function to write the DBD
    information that are used for unload in the USR file, and
    enables FPA RELOAD function to check the consistency
    between the DBD information in the library that is specified
    in IMSACB DD and the DBD information in the USR files.
    This function is activated when the new keyword ACBCHK=YES is
    specified both in the unload job and the reload job.
    
    ========================
    = DOCUMENTATION CHANGE =
    ========================
    The IMS High Performance Fast Path Utilities for z/OS User's
    Guide Version 3 Release 2 (SC18-9869-04).
    
    About DOCUMENTATION CHANGE, See
    http://www-01.ibm.com/support/docview.wss?rs=434&context=SSZJXP
    &context=SSUSPA&context=SSUSPS&q1=SC18-9869-04&uid=swg27015322
    &loc=en_US&cs=utf-8&lang=en
    320Y
    HFPCCCT0
    HFPCCDT0
    HFPCDEF0
    HFPCSUP0
    HFPFMAN0
    HFPFTSK0
    HFPFTTI0
    HFPFUSR0
    HFPJIUS0
    HFPJOMN0
    HFPKACT0
    HFPKIMN0
    HFPKIUS0
    HFPLCC10
    HFPLDBR0
    HFPLIOR0
    HFPLMAN0
    HFPRCDB0
    HFPRMAN0
    HFPSCDF0
    HFPSDBR0
    HFPSDBW0
    HFPTUSR0
    HFPUMVT0
    HFPUROB0
    HFPUSNC0
    HFPWMTC0
    HFPWMTJ0
    HFPWMTS0
    HFPZCCT
    HFPZDDT
    HFPZFCT
    HFPZMVT
    HFPZROB
    HFPZTTT
    HFPZUSR
    H31A320J
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM23240

  • Reported component name

    IMS HP FP UTILI

  • Reported component ID

    5655K9400

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2010-09-24

  • Closed date

    2011-02-23

  • Last modified date

    2011-03-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PM33340 UK65169

Modules/Macros

  •    HFPCCCT0 HFPCCDT0 HFPCDEF0 HFPCSUP0 HFPFMAN0
    HFPFTSK0 HFPFTTI0 HFPFUSR0 HFPJIUS0 HFPJOMN0 HFPKACT0 HFPKIMN0
    HFPKIUS0 HFPLCC10 HFPLDBR0 HFPLIOR0 HFPLMAN0 HFPRCDB0 HFPRMAN0
    HFPSCDF0 HFPSDBR0 HFPSDBW0 HFPTUSR0 HFPUMVT0 HFPUROB0 HFPUSNC0
    HFPWMTC0 HFPWMTJ0 HFPWMTS0 HFPZCCT  HFPZDDT  HFPZFCT  HFPZMVT
    HFPZROB  HFPZTTT  HFPZUSR  H31A320J
    

Publications Referenced
SC18986904    

Fix information

  • Fixed component name

    IMS HP FP UTILI

  • Fixed component ID

    5655K9400

Applicable component levels

  • R320 PSY UK65169

       UP11/02/25 P F102

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89D","label":"IMS HP Fast Path Utilities"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: