IBM Support

PM23041: Unacceptable big 'Records Lost' numbers in BPA CRD batch job.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • BPA CRD Write Task I/O functionality improvements. BPA CRD code
    needs to be optimized for profiling so that trace records are
    not lost.
    

Local fix

  • n/a
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   Buffer Pool Analyzer                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: Unacceptable big 'Records Lost' numbers *
    *                      reported in BPA CRD batch job.          *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    *                                                              *
    ****************************************************************
    PROBLEM SUMMARY:
    With CPU utilization coming close to 100% BPA CRD job I/O may
    suffer from the lack of dispatching priority which causes trace
    data loss.
    
    PROBLEM CONCLUSION:
    Code changed to fix this problem. Added capability to adjust
    write task I/O dispatching priority when BPA CRD job started
    APF authorized.
    

Problem conclusion

  • Code changed to fix this problem. Added capability to adjust
    write task I/O dispatching priority when BPA CRD job started
    APF authorized.
    
    KEYWORDS :    BPA CRD BATCH RECORDS LOST
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM23041

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-09-22

  • Closed date

    2010-12-13

  • Last modified date

    2011-01-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK62992 UK62993 UK62994

Modules/Macros

  • BPOMAB00 BPOMAWRT DGOVAB   HKDB410J HKDB420J
    HKDB510J KDB410J  KDB420J  KDB510J
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R410 PSY UK62992

       UP10/12/14 P F012

  • R420 PSY UK62993

       UP10/12/15 P F012

  • R510 PSY UK62994

       UP10/12/15 P F012

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
03 January 2011