A fix is available
APAR status
Closed as program error.
Error description
With APAR PK72688 on, there is checking of log records to ensure they are consecutive when running a SELECT step. If the log records are not consecutive, the read log stops and select ends with RC=08 and a message as follows: IQC3025E Base CheckPoint not found . QCF code change will provide a new error message in such rare case if this occurs.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of QCF3.1 , which use * * RECOVERDM, RECOVERAB, REPROCESS procedures * * with logs in LOGIN DD (without aitomatic * * log selection). * **************************************************************** * PROBLEM DESCRIPTION: If the logs are set in LOGIN DD for * * IQCSELCT step and the logs are out of * * order - the process ends with RC=08 * * and without some error messages. * * * * This APAR adds info as follows: * * If the logs are set in LOGIN DD for * * IQCSELCT step and the logs are out of * * order - new messages show: * * IQC3116E Timestamp and LSN of log * * record out of order- nnnnnn * * The step ends with RC=08. * * IQC3117E Timestamp of log * * record out of order- nnnnnn * * The step ends with RC=08. * * IQC3118I LSN of log * * record out of order- nnnnnn * * Processing continues. * **************************************************************** * RECOMMENDATION: Install the APAR to have info if the logs * * are put in LOGIN DD in IQCSELCT step * * not in the order they have been created. * **************************************************************** Install the APAR.
Problem conclusion
Install the APAR.
Temporary fix
Comments
APAR Information
APAR number
PM22530
Reported component name
IMS QUEUE CNTL
Reported component ID
5697E9900
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2010-09-14
Closed date
2010-10-15
Last modified date
2010-11-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK61401
Modules/Macros
IQCSMSG0 IQCSSUB6
Fix information
Fixed component name
IMS QUEUE CNTL
Fixed component ID
5697E9900
Applicable component levels
R310 PSY UK61401
UP10/10/16 P F010
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.