IBM Support

PM22223: ZDFVS DISTRIBUTED DATA FACILITY VTAM SUMMARY LIMITED TO 200 CONNECTIONS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Classic screen ZDFVS has a fixed limit of 200 distributed
    threads. If there are more than 200 threads they will not be
    displayed on this screen.
    

Local fix

  • Do not increase MAXDBAT beyond the "200" default"
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   Classic Interface                        *
    *                 -   CUA Interface                            *
    ****************************************************************
    * PROBLEM DESCRIPTION: ZDFVS DISTRIBUTED DATA FACILITY VTAM    *
    *                      SUMMARY LIMITED TO 200 CONNECTIONS      *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    *                                                              *
    ****************************************************************
    PROBLEM SUMMARY:
    ROUTINE DID NOT CHECK THE LIMIT OF CONNECTIONS WHICH CAN CAUSE
    AN OVERLAY OF OTHER PROGRAMS MEMORY.
    
    PROBLEM CONCLUSION:
    CHANGE LOGIC TO REMOVE LIMIT FOR THE CONNECTIONS NUMBER AND ADD
    THE CHECK FOR THE END OF OUTPUT AREA.
    

Problem conclusion

  • CHANGE LOGIC TO REMOVE LIMIT FOR THE CONNECTIONS NUMBER AND ADD
    THE CHECK FOR THE END OF OUTPUT AREA.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM22223

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2010-09-09

  • Closed date

    2011-08-30

  • Last modified date

    2017-02-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK71445 UK71446 UK71447

Modules/Macros

  •    KD2VDSSD KD2VDTDD KO2APCFA KO2APCFK KO2APCF2
    KO2CCINB KO2CDFCA KO2CDFCS KO2CDFC2 KO2CDFSA KO2CDFSK KO2CDFSS
    KO2CDFS2 KO2CTHQA KO2CTHQK KO2CTHQ2 KO2CTHSA KO2CTHSS KO2CTHS2
    KO2CVTIC KO2CVTIF KO2CVTIG KO2CVTSC KO2CVTSF KO2CVTSG KO2DFSTH
    KO2DISTH KO2DXS1A KO2DXS1K KO2DXS12 KO2HDFDH KO2HDFSH KO2ODSTB
    KO2OEVCB KO2OINTB KO2OSUBB KO2OTHBB KO2RSUMH KO2XDFSA KO2XDFSK
    KO2XDFS2 KO2XVTIF KO2XVTIG KO2XVTSF KO2XVTSG
    

Publications Referenced
SH12692401    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R410 PSY UK71445

       UP11/09/01 P F108

  • R420 PSY UK71446

       UP11/09/01 P F108

  • R510 PSY UK71447

       UP11/09/01 P F108

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"420","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"420","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
04 February 2017