IBM Support

PM21943: QMF V910 ABEND0C4 RC11 IN DSQISDT8 AT X'CCC'

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • S0C4 RC11 in DSQISDT8 +x'CCC' issuing SAVE DATA AS command
    ( AbendS0C4 RSN11 abend0c4-11 )
                                    .
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All QMF TSO/CICS V910 users.                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABENDS0C4 ABEND0C4 occurs in            *
    *                      DSQISDT8 after a SAVE DATA command.     *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The instruction that moved user data from one buffer to another
    during SAVE DATA processing was incorrectly coded and moved
    one byte too many.  When the FROM buffer field is at the very
    end of the buffer storage allocated, the one byte extra can be
    in fetch protected storage, thus causing an ABENDS0C4 PIC11.
    

Problem conclusion

  • The move data instruction was corrected.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM21943

  • Reported component name

    QMF-QUERY MGMT

  • Reported component ID

    566872101

  • Reported release

    910

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-09-03

  • Closed date

    2010-09-15

  • Last modified date

    2010-10-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK60503

Modules/Macros

  • DSQFSDT8 DSQISDT8
    

Fix information

  • Fixed component name

    QMF-QUERY MGMT

  • Fixed component ID

    566872101

Applicable component levels

  • R910 PSY UK60503

       UP10/09/21 P F009

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.