PM21920: SEVERAL PROBLEMS FOUND IN INTERNAL TEST

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • This APAR will provide the fix for several problems, that are
    found in the internal test.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for z/OS *
    *                 Version 4 Release 2 users ( FMID=H1J0420 )   *
    ****************************************************************
    * PROBLEM DESCRIPTION: This APAR provides the fix for the      *
    *                      following problem as a forward fit for  *
    *                      PM21169 of HP Image Copy V4R1:          *
    *                      -HPIC Recovery function ends with RC=8  *
    *                       and MSG DFS301A ( MSGDFS301A ) when    *
    *                       FREE=CLOSE is specified on DD card for *
    *                       image copy data set in JCL.            *
    *                                                              *
    *                      This APAR also fixes the following      *
    *                      problem:                                *
    *                      -HP Image Copy terminates with ABEND    *
    *                       S0C4 ( ABEND0C4 ) at FABJDPSA +        *
    *                       X'775E' when all of the following      *
    *                       conditions are satisfied:              *
    *                       1. Running under IMS Fast Path         *
    *                          Advanced Tool.                      *
    *                       2. Using stacking image copies         *
    *                          function.                           *
    *                       3. Having I/O error.                   *
    *                       4. Existing unprocessed DBDS.          *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    This APAR provides the fix for the following problem as a
    forward fit for PM21169 of HP Image Copy V4R1:
    -HPIC Recovery function ends with RC=8 and MSG DFS301A
     ( MSGDFS301A ) when FREE=CLOSE is specified on DD card for
     image copy data set in JCL.
    
    The causes of the problem are as follows:
    - HPIC Recovery function checks whether the image copy data set
      is in the Fast Recovery Image Copy format or not prior to the
      recovery processing, when image copy data set exists on DASD.
    - When FREE=CLOSE is specified on DD card for the input image
      copy data set, the DD is deallocated by the CLOSE call of
      the format check process. Then, the OPEN call fails in the
      recovery process because the DD has already been deallocated.
    
    
    This APAR also fixes the following problem:
    -HP Image Copy terminates with ABEND S0C4 ( ABEND0C4 ) at
     FABJDPSA + X'775E' when all of the following conditions are
     satisfied:
     1. Running under IMS Fast Path Advanced Tool.
     2. Using stacking image copies function.
     3. Having I/O error.
     4. Existing unprocessed DBDS.
    
    The cause of the problem is HP Image Copy has the unnecessary
    logic which points the incorrect internal control block address.
    

Problem conclusion

  • FABJRDB9,FABJRDBA and FABJRDBB have been modified to issue the
    CLOSE call with LEAVE option when FREE=CLOSE is specified on DD
    card for image copy data set in JCL.
    
    FABJDPSN has been modified to bypass the unnecessary logic.
    
    FABJDPS9, FABJDPSA and FABJDPSB have been reassembled.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM21920

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2010-09-06

  • Closed date

    2010-09-15

  • Last modified date

    2010-10-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK60465

Modules/Macros

  • FABJDPSA FABJDPSB FABJDPSN FABJDPS9 FABJRDBA
    FABJRDBB FABJRDB9
    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R420 PSY UK60465

       UP10/09/17 P F009

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"4.2.0","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
14 December 2020