A fix is available
APAR status
Closed as program error.
Error description
HPSU3561W THE ACCESS TO OUTPUT REPOSITORY WAS CANCELED. REASON: ITKBLOAD NOT AUTHORIZED received even though IMS Tools Knowledge Base library is APF- authorized.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM IMS High Performance Unload * * for z/OS Version 1 Release 2 (FMID=H1IN120). * **************************************************************** * PROBLEM DESCRIPTION: HPSU3561W is issued even if the * * ITKBLOAD control statement is * * specified correctly. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** This APAR fixes the following problems: 1. When the IMS Tools KB (ITKB) load module library is in the APF list and it is placed on the SMS-managed volumes, HPSU3561W (REASON: ITKBLOAD NOT AUTHORIZED) is issued incorrectly and the IPR Unload utility ends with RC=04. This issue occurrs when STEPLIB is APF-authorized. 2. When the name of ITKB load module library specified on the ITKBLOAD control statement in the HPSIN data set is shorter than the name which is defined in the installation default option table (HPSCOPTI), HPSU3561W (REASON: ITKBLOAD DYNALLOC FAILURE) is issued incorrectly and IPR Unload ends with RC=04.
Problem conclusion
The modules HPSUAPF0 and HPSU015 have been modified to treat the ITKB load module library correctly.
Temporary fix
Comments
APAR Information
APAR number
PM20195
Reported component name
IMS HIGHPERF UN
Reported component ID
5655E0600
Reported release
120
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2010-08-09
Closed date
2010-08-19
Last modified date
2010-09-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK59801
Modules/Macros
HPSUAPF0 HPSU015
Fix information
Fixed component name
IMS HIGHPERF UN
Fixed component ID
5655E0600
Applicable component levels
R120 PSY UK59801
UP10/08/20 P F008
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10"},"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSCX89K","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.2.0"}]
Document Information
Modified date:
20 October 2020