IBM Support

PM17339: DGOVM002+112A ABEND23E-08 FPEV0002S NUMBER 282,CODE 8 FPEV0002S NUMBER 58, CODE 8

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • FPEV0002S  DBT1 INTERNAL ERROR. NUMBER 282, CODE 8
    FPEV0002S  DBT1 INTERNAL ERROR. NUMBER 58,  CODE 8
    FPEV9999I **** DB2 PM/PE SYMPTOM RECORD ****
    FPEV9999I LVLS/OMEGAMON XE PE/PM
    FPEV9999I AB/S/23E
    FPEV9999I RIDS/FPEVM000#l
    FPEV9999I RIDS/DGOVM002
    FPEV9999I PTFS/ 2009.247 V4
    FPEV9999I ADRS/112C
    FPEV9999I PSW /070C1000 8139D048
    IEA995I SYMPTOM DUMP OUTPUT 338
    SYSTEM COMPLETION CODE=23E  REASON CODE=00000008
     TIME=10.05.06  SEQ=24963  CPU=0040  ASID=0097
     PSW AT TIME OF ERROR  070C1000   8139D048  ILC 2  INTC 0D
       NO ACTIVE MODULE FOUND  NAME=UNKNOWN
       DATA AT PSW  0139D042 - 00181610  0A0D50E0  D0049180
    Followed by:
    ================================================================
    2010/06/16 07:25:44 IEA995I SYMPTOM DUMP OUTPUT  199
    SYSTEM COMPLETION CODE=0C4  REASON CODE=00000011
     TIME=07.25.43  SEQ=29999  CPU=0000  ASID=00B5
     PSW AT TIME OF ERROR  078D0000   8D76D6CA  ILC 4  INTC 11
       ACTIVE LOAD MODULE           ADDRESS=0D76AD10
    OFFSET=000029BA
       NAME=FPEVM000
       DATA AT PSW  0D76D6C4 - 58308000  18A95EA0  300850A0
    ================================================================
    2010/06/16 07:25:45 IEA995I SYMPTOM DUMP OUTPUT  218
    SYSTEM COMPLETION CODE=0C4  REASON CODE=00000011
     TIME=07.25.44  SEQ=30000  CPU=0000  ASID=00B5
     PSW AT TIME OF ERROR  078D0000   8D7C66CA  ILC 4  INTC 11
       ACTIVE LOAD MODULE           ADDRESS=0D7C3D10
    OFFSET=000029BA
       NAME=FPEVM000
       DATA AT PSW  0D7C66C4 - 58308000  18A95EA0  300850A0
    ================================================================
    2010/06/16 07:25:45 IEA995I SYMPTOM DUMP OUTPUT  237
    SYSTEM COMPLETION CODE=0C4  REASON CODE=00000011
     TIME=07.25.44  SEQ=30001  CPU=0000  ASID=00B5
     PSW AT TIME OF ERROR  078D2000   8E3FEE8A  ILC 4  INTC 11
       ACTIVE LOAD MODULE           ADDRESS=0E3FC028
    OFFSET=00002E62
       NAME=FPEZPMS
       DATA AT PSW  0E3FEE84 - 60004180  00044820  31005420
    ================================================================
    2010/06/16 07:25:45 IEA995I SYMPTOM DUMP OUTPUT  238
    SYSTEM COMPLETION CODE=0C4  REASON CODE=00000011
     TIME=07.25.44  SEQ=30002  CPU=0000  ASID=00B5
     PSW AT TIME OF ERROR  078D1000   8DBB3452  ILC 4  INTC 11
       ACTIVE LOAD MODULE           ADDRESS=0DB81028
    OFFSET=0003242A
       NAME=FPEZPMS
       DATA AT PSW  0DBB344C - 600041F0  03E85830  60784160
    ================================================================
    2010/06/16 07:25:46 IEA995I SYMPTOM DUMP OUTPUT  239
    SYSTEM COMPLETION CODE=0C4  REASON CODE=00000011
     TIME=07.25.45  SEQ=30003  CPU=0000  ASID=00B5
     PSW AT TIME OF ERROR  078D2000   8E3DFD66  ILC 4  INTC 11
       ACTIVE LOAD MODULE           ADDRESS=0E39CF80
    OFFSET=00042DE6
       NAME=FPEVSERV
       DATA AT PSW  0E3DFD60 - 05EF58E0  400058F0  E0405850
    ================================================================
    2010/06/16 07:25:46 IEA995I SYMPTOM DUMP OUTPUT  263
    SYSTEM COMPLETION CODE=0C4  REASON CODE=00000011
     TIME=07.25.45  SEQ=30004  CPU=0000  ASID=00B5
     PSW AT TIME OF ERROR  078D2000   8DB57D66  ILC 4  INTC 11
       ACTIVE LOAD MODULE           ADDRESS=0DB14F80
    OFFSET=00042DE6
       NAME=FPEVSERV
       DATA AT PSW  0DB57D60 - 05EF58E0  400058F0  E0405850
    ================================================================
    2010/06/16 07:25:47 IEA995I SYMPTOM DUMP OUTPUT  266
    SYSTEM COMPLETION CODE=0C4  REASON CODE=00000004
     TIME=07.25.46  SEQ=30007  CPU=0000  ASID=00B5
     PSW AT TIME OF ERROR  078D2000   8D12FADE  ILC 4  INTC 04
       ACTIVE LOAD MODULE           ADDRESS=0D12B798
    OFFSET=00004346
       NAME=DGOVMSTR
       DATA AT PSW  0D12FAD8 - 1F995090  66F05090  67084190
    ================================================================
    2010/06/16 07:25:47 IEA995I SYMPTOM DUMP OUTPUT  269
    SYSTEM COMPLETION CODE=0C4  REASON CODE=00000011
     TIME=07.25.47  SEQ=30010  CPU=0000  ASID=00B5
     PSW AT TIME OF ERROR  078D0000   8D13159A  ILC 4  INTC 11
       ACTIVE LOAD MODULE           ADDRESS=0D12B798
    OFFSET=00005E02
       NAME=DGOVMSTR
       DATA AT PSW  0D131594 - 58308000  18A95EA0  300850A0
    ================================================================
    Can also experience S0C1 abends also.
    Keywords:
    23E ABEND23E S23E 0C4 ABEND0C4 S0C4 DGOVMSTR
    FPEV5009I DBD1 Response invalid:
    FPEV5009I DBD1 Return code .......... : 8 (00000008x)
    FPEV5009I DBD1 Reason code .......... : 5 (00000005x)
    FPEV5009I DBD1 Detecting module ..... : DGOVMSTR
    FPEV5009I DBD1 Error message ........ :
    +--------------------------------------------------------------+
    FPEV5009I DBD1 VALUE IN RESPONSE DATASET LINE 26 INCORRECT.
    FPEV5009I DBD1 MUST BE BETWEEN 1 AND  8 CHARACTERS.
    +--------------------------------------------------------------+
    FPEV5009I DBD1  User action .......... :
    +--------------------------------------------------------------+
    FPEV5009I DBD1  CORRECT RESPONSE DATASET AND RESTART SERVER.
    +---------------------------------------------------------------
    FPEV0275E MSTR ERROR WHEN PREPARING PE SERVER SUBTASK.
    MONITORING FOR DB2 SUBSYSTEM DBD1 IS DISABLED
    STOGROUP value not specified for all PWH performance warehouse
    tablespaces
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   PE Server subtask                        *
    *                 -   Performance Warehouse users              *
    ****************************************************************
    * PROBLEM DESCRIPTION: During OMEGAMON Collector start up a    *
    *                      PE Server subtask issues messages       *
    *                      FPEV0002S with internal error numbers   *
    *                      282 and 58 and terminates with Abend    *
    *                      23E.                                    *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    *                                                              *
    ****************************************************************
    PROBLEM SUMMARY:
    During OMEGAMON Collector start up PE Server reads the parameter
    data set members provided in RKD2PAR. An error in a parameter
    member results in an incomplete initialization of the starting
    PE Server subtask. The PE Server subtask reports the internal
    errors number 282 and 58 and discontinues processing. During
    termination the PE Server subtask tries to detach a subtask
    which had not been attached during initialization and causes
    Abend 23E.
    
    
    PROBLEM CONCLUSION:
    When the PE Server detects an error in the parameter data set
    members, the error condition is issued to the server log and
    monitoring for the corresponding DB2 Subsystem is disabled.
    New messages FPEV0273I, FPEV0274E and FPEV0275E were created.
    

Problem conclusion

  • When the PE Server detects an error in the parameter data set
    members, the error condition is issued to the server log and
    monitoring for the corresponding DB2 Subsystem is disabled.
    New messages FPEV0273I, FPEV0274E and FPEV0275E were created.
    
    
    The service level of the
    OMEGAMON collector PE Server subtask
    
    FPEV0114I  PTF BUILD IS 10.202
    
    KEYWORDS :
    FPEV0002S INTERNAL ERROR NUMBER 282 CODE 8 NUMBER 58 CODE 8
    ABEND 23E
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

APAR Information

  • APAR number

    PM17339

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-06-28

  • Closed date

    2010-07-22

  • Last modified date

    2010-09-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK59001

Modules/Macros

  • DGO@DB2I DGOVDB2I DGOVMB   DGOVMSTR DGOVM002
    DGOVZRAC DGOZMB   FPEUMSGS FPEVMST2 FPEVTMEM FPEVZRAC
    

Publications Referenced
GC19250600    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R420 PSY UK59001

       UP10/08/04 P F008

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
14 September 2010