IBM Support

PM16647: ELAX abend received running programs with sysLib check digit functions when the first parameter is a NUM field

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Rational COBOL Runtime for zSeries V6.0.1:
    
    An ELAX abend is received running programs with sysLib check
    digit functions when the first parameter is a NUM field.
    
    The following sysLib functions are effected by this:
    
    - calculateChkDigitMod10 (text, checkLength, result)
    - calculateChkDigitMod11 (text, checkLength, result)
    - verifyChkDigitMod10 (input, checkLength, result)
    - verifyChkDigitMod11 (input, checkLength, result)
    
    The following is an example of the error messages that are
    displayed or written to the ELAD queue:
    
    ELA00093I An error occurred in program ADD1AXA, function MAIN
    ELA09974P Unhandled exception occurred.  EGL line: 001361
    ELA09973I Condition code: 9980
    ELA09966P No such library function with specified signature
              exception
    ELA00001I An error occurred in program ADD1AXA on statement
              number 1361. - Caused by -An error occurred in
    ELA00001I program ELASYS, function ******************* An error
              occurred in program ELASYS on statement number
    ELA00001I 1097 Condition code: 09980 ERROR CODE=00000000 Runtime
              exception
    

Local fix

  • A tempfix is available from support.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: USERS OF RATIONAL COBOL RUNTIME FOR ZSERIES  *
    ****************************************************************
    * PROBLEM DESCRIPTION: ELAX ABEND RECEIVED RUNNING PROGRAMS    *
    *                      WITH SYSLIB CHECK DIGIT FUNCTIONS WHEN  *
    *                      THE FIRST PARAMETER IS A NUM FIELD      *
    ****************************************************************
    * RECOMMENDATION: APPLY THIS MAINTENANCE                       *
    ****************************************************************
    ELAX ABEND RECEIVED RUNNING PROGRAMS WITH SYSLIB CHECK DIGIT
    FUNCTIONS WHEN THE FIRST PARAMETER IS A NUM FIELD.
    

Problem conclusion

  • ELAX ABEND RECEIVED RUNNING PROGRAMS WITH SYSLIB CHECK DIGIT
    FUNCTIONS WHEN THE FIRST PARAMETER IS A NUM FIELD
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM16647

  • Reported component name

    RATL COBOL RT Z

  • Reported component ID

    5655R2900

  • Reported release

    601

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-06-16

  • Closed date

    2010-09-17

  • Last modified date

    2010-11-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PM16649 PM16824

Modules/Macros

  • ELASYS
    

Fix information

  • Fixed component name

    RATL COBOL RT Z

  • Fixed component ID

    5655R2900

Applicable component levels

  • R601 PSY UK60551

       UP10/10/07 P F010

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSN27B","label":"Rational COBOL Runtime for zSeries"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.1","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: