A fix is available
APAR status
Closed as new function.
Error description
This APAR provides the added functionality to HPIC V4.2.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Image Copy for z/OS * * Version 4 Release 2 users ( FMID=H1J0420 ) * **************************************************************** * PROBLEM DESCRIPTION: This APAR provides: * * - Functionality to HASH pointer check * * without creating image copies. * * With this function, user can perform * * HASH pointer check for online * * database. * * - zIIP processor support * * * * This APAR also includes fixes for some * * problems. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** This APAR includes following enhancements: 1. Functionality to HASH pointer check without creating image copies. For ICOUT= and STACK= keywords, a new parameter %NO is added in order not to create the image copy data set and not to register IC record in the DBRC RECON. This enhancement is intended for user to do HASH pointer check for online full function databases. It addresses FITS MR00040057, MR0129093327, and MR061109402. +-----------------------------------------------------+ | Pointer Checking for online full function database | +-----------------------------------------------------+ To perform pointer checking completely for full function database, it is required to capture static database image. In other words, online database should be stopped during pointer checking. Although this restriction inhibits the continuous database operation, it is unavoidable. To decrease this problem, take advantage of HPIC functions which are HPIC HASH Check with TOIAUTO (or TOIAUTO_Q) and FASTIC. By using these functions, HASH pointer check can be done for the online database with automatic start-stop operations and with short period of the database unavailable time. This run mode is called as a pseudo online pointer check mode. Here is a process flow of the HPIC pseudo online pointer check mode: 1. stop(/DBD or /DBR) or quiesce the database 2. create shadow data set by FlashCopy in short time 3. restart the database 4. perform HASH pointer check to the shadow data set 5. delete the shadow data set To do this, user need to specify following ICEIN keywords: - HDPC=Y to HASH pointer check - TOIAUTO_Q=Y or TOIAUTO=Y to suspend/stop and resume/restart databases while HASH pointer checking - FASTIC=(,FDUMP) or FASTIC=(,COPY) for shorter unavailable time of the databases. - ICOUT=%NO or STACK=%NO to suppress creating image copies The step 5 "delete the flash copy" is an optional. You can keep the data set as image copy, if you do not specify ICOUT=%NO or STACK=%NO. 2. zIIP processor support This enhancement is for FITS MR040309532 and MR1202075943. The new keyword ZIIPMODE= is added to offload CPU workload of HP Image Copy jobs to zIIP processors. For more detail, please refer HP Image Copy V4R2 DCF that will available later. When the DCF becomes available, this APAR information will be update so as to point the DCF document. This APAR also includes fixes for following problems: - HP Image Copy does not report the "Image Copy Dump Process report" that is generated in ICERPRT DD and "Data Set Statistics report" that is generated in FABJSTAT DD for index DB when all of the following conditions are satisfied: - Processing database is index DB. - FASTIC=(,COPY) or FASTIC=(,DUMP) or FASTIC=(,FDUMP) is specified. - Either VIC=Y and HDPC=N are specified or VIC=(Y,OFFPC) is specified. - HP Image Copy terminates with RC=08 and message FABJ0215E ( MSGFABJ0215E ), and also NOTIFY.UIC command is not issued to the index DB when all of the following conditions are satisfied: - Processing database is index DB. - FASTIC=(,FDUMP) is specified. - NOTIFYMODE=COND is specified. - Either VIC=Y and HDPC=N are specified or VIC=(Y,OFFPC) is specified. - HP Image Copy terminates with ABEND U3835 ( ABENDU3835 ) and message FABJ3835E ( MSGFABJ3835E ) for NOTIFY.IC command to the DL/I DB and HALDB when all of the following conditions are satisfied: - Processing database is DL/I DB or HALDB. - HP Image Copy is running in IMS V10 or higher. - The value of MINVERS in RECON data set is '9.1' or lower. - FASTIC=(,COPY) or FASTIC=(,DUMP) is specified. - NOTIFYMODE=COND is specified. - DBALL=(Y,Y) is specified. - HP Image Copy terminates without issuing a required NOTIFY.IC command to the secondary index DB or terminates with ABEND U3835 ( ABENDU3835 ) and message FABJ3835E ( MSGFABJ3835E ) for NOTIFY.IC command to the secondary index DB when all of the following conditions are satisfied: - Processing database are secondary index and secondary index overflow. - NOTIFYMODE=COND is specified. - HDPC=O is specified to either secondary index or secondary index overflow. - HP Image Copy Restart process issues the incorrect message FABJ4260I ( MSGFABJ4260I ) for database which has been successfully completed by checkpoint process. And if the database is DEDB, HP Image Copy may terminate with ABEND S0C4 ( ABEND0C4 ). - HP Image Copy is running in the restart mode. - RESTART=Y is specified and Checkpoint/Restart function is enabled. - FASTIC=(,COPY) or FASTIC=(,DUMP) is specified. - HP Image Copy issues the incorrect text of message FABJ9007I ( MSGFABJ9007I ). - The default value of SHDWTCTL= keyword is incorrect. Although SHDWTCTL=20 described by the User's guide is correct, SHDWTCTL=64 is applied as an incorrect default value.
Problem conclusion
Temporary fix
Comments
Following modules and macros are modified for this APAR: The following modules and macros have been modified. FABJACQG FABJBLKD FABJDBAL FABJDFCN FABJDMPN FABJDPSN FABJDSSB FABJFCBK FABJFCDN FABJGLRP FABJICDD FABJIDXN FABJMAIN FABJMAP1 FABJMRGE FABJMSGC FABJOFL1 FABJPARM FABJRPT1 FABJTGEN FABJTOI The following modules have been reassembled. FABJAPIM FABJASPM FABJATRC FABJCMDB FABJCRC0 FABJCRC1 FABJCRC3 FABJCTCV FABJCZCV FABJDALC FABJDALO FABJDALS FABJDBCM FABJDBC1 FABJDBDN FABJDBD9 FABJDBDA FABJDBDB FABJDBF0 FABJDBLK FABJDBRC FABJDBR9 FABJDBRA FABJDBRB FABJDCTL FABJDDIM FABJDEMP FABJDFC9 FABJDFCA FABJDFCB FABJDMP0 FABJDMP9 FABJDMPA FABJDMPB FABJDOPN FABJDPS9 FABJDPSA FABJDPSB FABJDPUT FABJDREQ FABJDRQS FABJDRSN FABJFCAI FABJFCCM FABJFCCN FABJFCC9 FABJFCCA FABJFCCB FABJFCD9 FABJFCDA FABJFCDB FABJFDMP FABJGDGB FABJIDX9 FABJIDXA FABJIDXB FABJINT1 FABJINT2 FABJINT3 FABJIPRC FABJMAS1 FABJMDPN FABJMDP9 FABJMDPA FABJMDPB FABJMSUL FABJNTFC FABJNTFI FABJNTFS FABJOFDD FABJOFL0 FABJORCN FABJORC9 FABJORCA FABJORCB FABJPRM2 FABJPRM3 FABJRCHK FABJRCH9 FABJRCHA FABJRCHB FABJRDB9 FABJRDBA FABJRDBB FABJRETC FABJRETM FABJRFCN FABJRFC9 FABJRFCA FABJRFCB FABJRPT0 FABJSAS1 FABJSAS2 FABJSTA FABJTERM FABJTOI2 FABJUIC1 FABJXCR FABJXHPC FABJXLIM ======================== = DOCUMENTATION CHANGE = ======================== Documentation Change for the new function is available in the Update document of IMS High Performance Image Copy for z/OS Version 4 Release 2 User's Guide SC19-2756-00 ( SC19275600 ) on http://www.ibm.com/software/data/db2imstools/library.html.
APAR Information
APAR number
PM15237
Reported component name
IMS HP IMAGE CO
Reported component ID
5655K9600
Reported release
420
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2010-05-25
Closed date
2010-06-28
Last modified date
2010-07-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK58346
Modules/Macros
FABJACQG FABJAPIM FABJASPM FABJATRC FABJBLKD FABJCMDB FABJCRC0 FABJCRC1 FABJCRC3 FABJCTCV FABJCZCV FABJDALC FABJDALO FABJDALS FABJDBAL FABJDBCM FABJDBC1 FABJDBDA FABJDBDB FABJDBDN FABJDBD9 FABJDBF0 FABJDBLK FABJDBRA FABJDBRB FABJDBRC FABJDBR9 FABJDCTL FABJDDIM FABJDEMP FABJDFCA FABJDFCB FABJDFCN FABJDFC9 FABJDMPA FABJDMPB FABJDMPN FABJDMP0 FABJDMP9 FABJDOPN FABJDPSA FABJDPSB FABJDPSN FABJDPS9 FABJDPUT FABJDREQ FABJDRQS FABJDRSN FABJDSSB FABJFCAI FABJFCBK FABJFCCA FABJFCCB FABJFCCM FABJFCCN FABJFCC9 FABJFCDA FABJFCDB FABJFCDN FABJFCD9 FABJFDMP FABJGDGB FABJGLRP FABJICDD FABJIDXA FABJIDXB FABJIDXN FABJIDX9 FABJINT1 FABJINT2 FABJINT3 FABJIPRC FABJMAIN FABJMAP1 FABJMAS1 FABJMDPA FABJMDPB FABJMDPN FABJMDP9 FABJMRGE FABJMSGC FABJMSUL FABJNTFC FABJNTFI FABJNTFS FABJOFDD FABJOFL0 FABJOFL1 FABJORCA FABJORCB FABJORCN FABJORC9 FABJPARM FABJPRM2 FABJPRM3 FABJRCHA FABJRCHB FABJRCHK FABJRCH9 FABJRDBA FABJRDBB FABJRDB9 FABJRETC FABJRETM FABJRFCA FABJRFCB FABJRFCN FABJRFC9 FABJRPT0 FABJRPT1 FABJSAS1 FABJSAS2 FABJSTA FABJTERM FABJTGEN FABJTOI FABJTOI2 FABJUIC1 FABJXCR FABJXHPC FABJXLIM
| SC19275600 |
Fix information
Fixed component name
IMS HP IMAGE CO
Fixed component ID
5655K9600
Applicable component levels
R420 PSY UK58346
UP10/07/01 P F006
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"4.2.0","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: