Error description
After UK54361, when adding a printer using the batch update utility, IZTUD1U0, the wrong default is set for parameter BYPLOGON=. The default was BYPLOGON=Y, rather than BYPLOGON=N.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS ETO Support V3.1 * **************************************************************** * PROBLEM DESCRIPTION: Multiple errors in the batch update * * utility (IZTUD1U0) * **************************************************************** * RECOMMENDATION: * **************************************************************** Multiple errors in the batch update utility (IZTUD1U0): - ZP sets wrong default value for BYPLOGON= - ZL for SLU2/3270 Nodes allowed invalid wildcards - ZR w/DELETE does not remove a single entry from the list, rather is deletes the entire record. OTMA Userdata not added to message when using IZTUDATA prefixed with IMSID IZTRAN SLU2/3270 Node entry - LTERM name with mask characters not getting saved unless SIGNON W/USERID also specified. Sub routine IZTSRCH0 invalid output - RCNT shows up as a SLU1 PRINTER
Problem conclusion
Code has been modified to correct the above problems.
Temporary fix
Comments
ž**** PE11/06/03 FIX IN ERROR. SEE APAR PM34021 FOR DESCRIPTION
APAR Information
APAR number
PM15218
Reported component name
IMS ETO SUPPORT
Reported component ID
5655E1200
Reported release
310
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-05-25
Closed date
2010-06-15
Last modified date
2011-06-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK57981
Modules/Macros
IZTCLNBA IZTCLNBB IZTCLNB7 IZTCLNB8 IZTCLNB9 IZTCSA02 IZTDCB IZTDUPD0 IZTINITA IZTINITB IZTINIT7 IZTINIT8 IZTINIT9 IZTINTXZ IZTINTX0 IZTJUPD4 IZTMUPD0 IZTNUPD0 IZTSMU IZTSRCHA IZTSRCHB IZTSRCH7 IZTSRCH8 IZTSRCH9 IZTSUPD0 IZTUD1U0 IZTYDRUA IZTYDRUB IZTYDRU7 IZTYDRU8 IZTYDRU9
| SC18903603 |
Fix information
Fixed component name
IMS ETO SUPPORT
Fixed component ID
5655E1200
Applicable component levels
R310 PSY UK57981
UP10/06/19 P F006
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX897","label":"IMS ETO Support"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
03 June 2011