Error description
ITKB command processor needs ability to process commands in sequence submitted. Also needs the ability to wait for the complete set of commands be executed successfully before returning a RC=0 within an ITKB Batch job. When STO and STA command are issued via batch, the STA command starts before the end of the STO. STOP and START commands request an asynchronous process to be initiated. When the START is attempted before the asynchronous process is requested by the STOP, the request completes and the START is likely to fail. This is based off of ITKB V110 FITS REQ MR0226106746. This is a forward fit of ITKB V110 APAR PM14285.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users utilizing the FPQBATCH repository * * STOP and START commands. * **************************************************************** * PROBLEM DESCRIPTION: A new parameter, MAXWAIT, is added to * * the FPQBATCH repository STOP and START * * commands. When specified this * * parameter controls the maximum amount * * of time to wait for the completion of * * the command and what return code to set * * if the command does not complete in the * * specified amount of time. The default * * is MAXWAIT(5,IGNORE) * * it will wait up to five seconds for * * completion and will not modify the * * condition code. Previously there was * * no wait for the completion of the * * command. JCL examples are updated to * * include specification of this * * parameter. * **************************************************************** * RECOMMENDATION: * **************************************************************** The MAXWAIT parameter is added to the STOP and START commands allowing the job step to wait for completion so that the data sets can be processed in a subsequent step.
Problem conclusion
Temporary fix
Comments
Documentation for PTFs that affects IMS Tools Knowledge Base V1.1 (SC18-9963-02) and IMS Tools Base: IMS Tools Knowledge Base V1.1 (SC19-2895-00) can be found on the IBM IMS Tools Product Publications page: http://www-01.ibm.com/software/data/db2imstools/ imstools-library.html Click on the "See updates to this book!" link for the appropriate user guide to view the TechDoc that contains the updated and corrected documentation. The actual link to this TechDoc is: http://www-01.ibm.com/support/docview.wss?uid=swg27018662
APAR Information
APAR number
PM14294
Reported component name
IMS TOOLS BASE
Reported component ID
5655V9300
Reported release
110
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2010-05-11
Closed date
2010-06-15
Last modified date
2010-07-01
APAR is sysrouted FROM one or more of the following:
PM14285
APAR is sysrouted TO one or more of the following:
UK57993
Modules/Macros
FPQBATCH FPQBCPL FPQCLVER FPQCSRV FPQM4ENU FPQREPST FPQSMSES FPQSREQQ FPQSRV FPQSRVPL FPQSTDMP FPQXHDR FPQXHDRB HKTADREP HKTALSR HKTAS010 HKTBAKUP HKTREORG HKTXACC HKTZGCB HKTZIN00 HKTZPRIM HKTZPRMR HKTZPR00
| SC19289500 |
Fix information
Fixed component name
IMS TOOLS BASE
Fixed component ID
5655V9300
Applicable component levels
R110 PSY UK57993
UP10/06/17 P F006
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCJN3E","label":"IBM Tools Base"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0"}]
Document Information