Error description
ERROR DESCRIPTION: HCOZLDE0, and other like programs, cannot handle input files bigger than 4 G - invalid before and after compress values shown UK56288 did not correct this. Additional keywords: kbytes used avg lgth dictionary function detail analyze
Local fix
Although the statistics for before and after compress are not correct, a valid dictionary is built and used.
Problem summary
**************************************************************** * USERS AFFECTED: All HDCE users who run the Detail Analyze * * function with more than 8 gigabytes of input * * data for a segment. * **************************************************************** * PROBLEM DESCRIPTION: Invalid kilobyte totals are shown on * * report HCO006 when the amount of input * * data for a segment exceeded 8 * * gigabytes. * **************************************************************** * RECOMMENDATION: * **************************************************************** The accumulators defined in HCOZLDE0 were too small.
Problem conclusion
The accumulator sizes were increased in HCOZLDE0 and report HCO006 was redesigned to show values in gigabytes instead of kilobytes, which results in a cleaner a more meaningful report.
Temporary fix
Comments
APAR Information
APAR number
PM13550
Reported component name
IMS TOOLS BASE
Reported component ID
5655V9300
Reported release
110
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2010-05-03
Closed date
2010-05-13
Last modified date
2010-06-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
PM13594 UK56948
Modules/Macros
HCOZLDE0
| SC27100503 |
Fix information
Fixed component name
IMS TOOLS BASE
Fixed component ID
5655V9300
Applicable component levels
R110 PSY UK56948
UP10/05/15 P F005 Ø
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCJN3E","label":"IBM Tools Base"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0"}]
Document Information
Modified date:
19 October 2020