IBM Support

PM12952: CEXPUBMN DURING SHUTDOWN OF IMS CONNECT 10/05/18 PTF PECHANGE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • - An 0C4 can occur in CEXPUBMN at during shutdown of IMS
    Connect. The offset is at x'4844' when CEXPUBMN is at level
    PK79885 but the abend could occur at other levels of CEXPUBMN.
    - An ABEND32E rsn=11C can occur after APAR PM04642 when running
    the Publisher API
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IMS Connect Extensions V2.1         *
    ****************************************************************
    * PROBLEM DESCRIPTION: An 0C4 can occur in CEXPUBMN during     *
    *                      shutdown of IMS Connect.                *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    This APAR is correcting the following problems:
    1.An 0C4 can occur in CEXPUBMN during shutdown of IMS Connect.
    The offset is at 004844 when CEXPUBMN is at level PK79885 but
    the abend could occur at other levels of CEXPUBMN.
    2.An Abend 32E rsn=11C can occur after APAR PM04642 when
    running the Publisher API.
    

Problem conclusion

  • The following changes have been made for the above problems:
    1.Corrected CEXPUBMN to properly handle the error condition
    where the publisher clients MTT control block is not present.
    2.Corrected CEXAPMT1 to properly issue STIMERM request and
    avoid Abend 32E.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM12952

  • Reported component name

    FUNC SUPP LIBRA

  • Reported component ID

    5655K4801

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2010-04-23

  • Closed date

    2010-05-21

  • Last modified date

    2010-06-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK57168

Modules/Macros

  • CEXAPMT1 CEXPUBMN
    

Fix information

  • Fixed component name

    IMS CONNECT EXT

  • Fixed component ID

    5655K4800

Applicable component levels

  • R210 PSY UK57168

       UP10/05/26 P F005 «

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88S","label":"IMS Connect Extensions"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"210"}]

Document Information