Fixes are available
Rational ClearQuest Fix Pack (7.1.2.5) for version 7.1.2
Rational ClearQuest Fix Pack (8.0.0.1) for version 8.0
Rational ClearQuest Fix Pack 14 (7.1.2.14) for 7.1.2
Rational ClearQuest Fix Pack 11 (8.0.0.11) for 8.0
Rational ClearQuest Fix Pack 12 (8.0.0.12) for 8.0
Rational ClearQuest Fix Pack 15 (7.1.2.15) for 7.1.2
Rational ClearQuest Fix Pack 13 (8.0.0.13) for 8.0
Rational ClearQuest Fix Pack 16 (7.1.2.16) for 7.1.2
Rational ClearQuest Fix Pack 17 (7.1.2.17) for 7.1.2
Rational ClearQuest Fix Pack 14 (8.0.0.14) for 8.0
Rational ClearQuest Fix Pack 18 (7.1.2.18) for 7.1.2
Rational ClearQuest Fix Pack 15 (8.0.0.15) for 8.0
Rational ClearQuest Fix Pack 19 (7.1.2.19) for 7.1.2
Rational ClearQuest Fix Pack 16 (8.0.0.16) for 8.0
Rational ClearQuest Fix Pack 17 (8.0.0.17) for 8.0
Rational ClearQuest Fix Pack 18 (8.0.0.18) for 8.0
Rational ClearQuest Fix Pack 19 (8.0.0.19) for 8.0
Rational ClearQuest Fix Pack 20 (8.0.0.20) for 8.0
Rational ClearQuest Fix Pack 21 (8.0.0.21) for 8.0
APAR status
Closed as program error.
Error description
The following error is through when loading a schema in the CQ Designer 7.1.1 Unable to load Schema Revision Reason: Unable to load Schema Revision Details: Unable to load Schema Revision Error reported by ClearQuest while building the XML Schema document : An invalid argument was encountered.. Steps to reproduce: 1.Open CQ Designer (eclipse) 2.Create a field with a choice list 3.Set the Default Value column for the new field 4.Select 'constant' 5.Put in a space for the constant value 6.Save the schema 7.Close the schema 8.Open CQ Designer (eclipse) 9.Open the schema 10.Receive error message Work around is to use the old CQ designer
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** CQ Eclipse Designer 7.1.1 users receive an "Unable to load Schema Revision" error when opening a schema under the following condition: the schema has a record with a choice list field where the constant default value is a space ("").
Problem conclusion
A fix is available in ClearQuest 7.1.1.8, 7.1.2.5 and 8.0.0.1
Temporary fix
Comments
APAR Information
APAR number
PM12398
Reported component name
CLEARCASE WIN
Reported component ID
5724G2900
Reported release
711
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-04-15
Closed date
2011-12-16
Last modified date
2011-12-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CLEARQUEST WIN
Fixed component ID
5724G3600
Applicable component levels
R711 PSN
UP
Document Information
Modified date:
16 December 2011