A fix is available
APAR status
Closed as program error.
Error description
This APAR is forwardfit of HPIC V4.1 PM11739. HPIC uses incorrect blocking factor for overflow data set of HISAM and S-Index, when using FASTIC=( ,DUMP) and IC process under IPR or DB Reorg Expert. As the result, output IC record is incorrect.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Image Copy for z/OS * * Version 4 Release 2 users ( FMID=H1J0420 ) * **************************************************************** * PROBLEM DESCRIPTION: This APAR includes following APAR of * * IMS HP Image Copy V4R1: * * PM11739 * * * * HP Image Copy terminates with RC=00 * * but creates the incorrect image copy * * data set for the overflow data set of * * HISAM or SINDEX when one of the * * following running process: * * * * - FASTIC=(,DUMP) * * - Type-A process of IMS Parallel * * Reorganization or IMS Reorganization * * Expert * * - Image copy process under * * IMS Database Recovery Facility * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** This APAR includes following APAR fix from IMS High Performance Image Copy for z/OS version 4 release 1: PM11739 fixes following problem: HP Image Copy terminates with RC=00 but creates the incorrect image copy data set for the overflow data set of HISAM or SINDEX when one of the following running process: - FASTIC=(,DUMP) - Type-A process of IMS Parallel Reorganization or IMS Reorganization Expert - Image copy process under IMS Database Recovery Facility The cause of the problem is that HP Image Copy calculates the value of the blocking factor for database record by incorrect method when processing the overflow data set for HISAM or SINDEX. As a result, the created image copy data set is incorrect and can not be used for the database recovery.
Problem conclusion
FABJFCDN, FABJDRQS and FABJDPUT have been modified to calculate the correct blocking factor for the overflow data set of HISAM or SINDEX. FABJFCD9, FABJFCDA and FABJFCDB have been reassembled.
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PM12290
Reported component name
IMS HP IMAGE CO
Reported component ID
5655K9600
Reported release
420
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2010-04-15
Closed date
2010-04-22
Last modified date
2010-05-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK56302
Modules/Macros
FABJDPUT FABJDRQS FABJFCDA FABJFCDB FABJFCDN FABJFCD9
Fix information
Fixed component name
IMS HP IMAGE CO
Fixed component ID
5655K9600
Applicable component levels
R420 PSY UK56302
UP10/04/23 P F004
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"4.2.0","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
14 December 2020