A fix is available
APAR status
Closed as program error.
Error description
The DB2 Administration Tool for z/OS Change Management ADBCCME - Merge Version Files step fails return code 12 with a message: MERGE REPORT ============ ADBCCME - Error(s) found. Please review output Unable to locate row to update when altering table ADBC002E - Severe error. Merge terminates when a RENAMECOL mask is used and a new column with the original renamed columns name is added.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Administration Tool for * * z/OS who use the old * * name of a renamed column for a * * new column in the same table. * **************************************************************** * PROBLEM DESCRIPTION: If an existing column has been * * renamed and a new column in * * the table has the old name of * * the renamed column, the Analyze * * ended with rc=12 and message: * * ADBCCME - Error(s) found. Please * * review output * * Unable to locate row to update when * * altering table. * **************************************************************** * RECOMMENDATION: Apply The PTF. * **************************************************************** If an existing column has been renamed and a new column in the table has the old name of the renamed column, the Analyze ended with rc=12 and message: ADBCCME - Error(s) found. Please review output Unable to locate row to update when altering table.
Problem conclusion
The problem has been resolved by OC APAR PM11261.
Temporary fix
Comments
APAR Information
APAR number
PM10756
Reported component name
DB2 ADMIN TOOL
Reported component ID
568851500
Reported release
720
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-03-24
Closed date
2010-09-23
Last modified date
2010-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK60744
Modules/Macros
GOC2CMT
Fix information
Fixed component name
DB2 OBJECT COMP
Fixed component ID
5697G6400
Applicable component levels
R720 PSY UK60744
UP10/09/30 P F009
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUVH","label":"IBM Db2 Object Comparison Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
02 October 2010