A fix is available
APAR status
Closed as program error.
Error description
Long CPU times have been detected when running in log-forward mode if 2 or more image copies are required for the same tablespace or partition. This does not occur in log-backward mode. This generally occurs only if the output of the job is substantial (>50000 rows) and most of the activity occurred within the context of the earlier image copy(s).
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Log Analysis Tool. * **************************************************************** * PROBLEM DESCRIPTION: Long CPU times have been detected when * * running in log-forward mode if 2 or * * more image copies are required for the * * same tablespace or partition. This does * * not occur in log-backward mode. This * * generally occurs only if the output of * * the job is substantial (>50000 rows) * * and most of the activity occurred * * within the context of the earlier * * image copy(s). * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
APPLY the PTF.
Temporary fix
Comments
APAR Information
APAR number
PM10557
Reported component name
DB2 LOG ANALYSI
Reported component ID
5655E6601
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2010-03-22
Closed date
2010-05-05
Last modified date
2010-06-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK56715 UK56716 UK56717
Modules/Macros
ALA#MREP ALAARC2 ALAA07 ALADTS ALAEXP ALAFA ALAGEN1 ALALF1 ALALF1A ALALF1B ALAMSP ALAPEXP ALAPGR ALAPGR2 ALAREC ALASUBG ALATVF
Fix information
Fixed component name
DB2 LOG ANALYSI
Fixed component ID
5655E6601
Applicable component levels
R230 PSY UK56715
UP10/05/12 P F005
R310 PSY UK56716
UP10/05/12 P F005
R320 PSY UK56717
UP10/05/12 P F005
Fix is available