IBM Support

PM09985: HPIC CHECKS DB AUTHORIZATION STATUS IN DBRC RECORD AGAIN UNTIL DB IS STOPPED.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • HPIC checks DB authorization status in DBRC record. HPIC do DBRC
    check over again until DB is stopped. The maximum time limit for
    response of /DBR and check interval are controlled by TOITIME=.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for z/OS *
    *                 Version 4 Release 1 users ( FMID=H1J0410 )   *
    ****************************************************************
    * PROBLEM DESCRIPTION: With this APAR, HPIC will check the DB  *
    *                      status over again after /DBR or /DBD    *
    *                      command is issued until the DB is       *
    *                      stopped or the maximum time limit for   *
    *                      response of /DBR or /DBD command.       *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    With this APAR, HPIC will check the DB status over again after
    /DBR or /DBD command is issued until the DB is stopped or the
    maximum time limit for response of /DBR or /DBD command.
    
    The maximum time limit and the check interval will be able to be
    controlled by the TOITIME= keyword.
    

Problem conclusion

  • FABJTOI and FABJDBIM have been modified to check the DB status
    in DBRC until DB is stopped or the time limit for response.
    
    FABJSTA has been reassembled.
    
    ========================
    = DOCUMENTATION CHANGE =
    ========================
    IMS High Performance Image Copy for z/OS Version 4 Release 1
    User's Guide SC18-9409-02 ( SC18940902 ) should be changed as
    follows:
    
    3.0 Operating instructions
    3.4 ICEIN control statement data set
    3.4.3 Option parameters
    3.4.3.78 TOITIME keyword
      where:
        :
      mmmm
        :
    | nnnn specifies, in milliseconds, the time interval of the DB
    | status check process that checks whether the DB, PART, or AREA
    | has been stopped or not. The valid value is 1 through 9999.
    | The default value is 100, which means 0.1 seconds.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM09985

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2010-03-15

  • Closed date

    2010-03-18

  • Last modified date

    2010-04-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK55309

Modules/Macros

  • FABJDBIM FABJSTA  FABJTOI
    

Publications Referenced
SC18940902    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R410 PSY UK55309

       UP10/03/20 P F003

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"4.1.0","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
14 December 2020