IBM Support

PM08345: TRACE EVENT RECORD 170 NOT PRODUCED FOR SCI SEND/RECEIVE EVENTS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • This APAR will address the following problems:
    - Trace event record 170 not produced for SCI send receive
      events
    - Recorder Trace Utility does not format ODBM trace records
      correctly when IPB/OPB data length is zero
    - TCPIP MAXSOC keyword can have leading zeros for IMS Connect
      parser without errors. The CEX parser generates an error
      if the leading zeros make the length of the keyword value
      more than 5 characters.
    - The CEX parser generates an error if some of the HWS CONFIG
      members keyword values begin with a numeric value.
    - ABEND0C4 CEXCETL +x'66BA' when running option CEXTRACE
      BUFSIZE=4.
    - MSGFUN2211I Syntax error at line  XX: the input RUNOPTS is
    not a known command
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IMS Connect Extensions V2.2         *
    ****************************************************************
    * PROBLEM DESCRIPTION: Trace event record 170 not produced     *
    *                      for SCI send/receive events.            *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    This APAR is correcting the following:
    1. Trace event record 170 not produced for SCI send/receive
    events.
    2. Recorder Trace Utility does not format ODBM trace records
    correctly when IPB/OPB data length is zero.
    3. TCPIP MAXSOC keyword can have leading zeros for IMS Connect
    parser without errors. The CEX parser generates and error if the
    leading zeros make the length of the keyword value more than 5
    characters.
    4. The CEX parser generates and error is some of the HWS CONFIG
    members keyword values begin with a number value
    5. A multi-segment input message from WAS may result in an
    invalid Client Id in the CEX Console Active session display.
    6. Remove event records for OTMA Degraded system monitoring
    heartbeat notification.
    7. An 0C4 can occur when the CEX OTMA trace is active and the
    size of the data being traced is only 1 or 2 bytes longer than
    the trace buffer size.
    

Problem conclusion

  • The following changes have been made for the above problems:
    1. Corrected module CEXTECL to produce the trace event when
    requested.
    2. Corrected utility to format ODBM trace records correctly.
    3. Corrected parser to accept leading zeros up to a maximum
    length of 6 characters. The resulting value of MAXSOC cannot
    exceed the IMS Connect allowed maximum of 65,535.
    4. Changed the CEX parser to allow keyword values to begin with
    a numeric character when the keyword value does not refer to a
    PDS member name.
    5. Corrected module CEXEVT01 to correctly process WAS
    multi-segment input message.
    6. Changed CEXTECL to not record events for system monitoring
    heartbeat messages.
    7. Corrected CEXTECL to properly track the amount of data that
    has been moved to the trace buffer.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM08345

  • Reported component name

    IMS CONNECT EXT

  • Reported component ID

    5655K4800

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2010-02-23

  • Closed date

    2010-04-26

  • Last modified date

    2011-07-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK56413

Modules/Macros

  • CEXBCMD0 CEXCR65  CEXEVT01 CEXMAIN  CEXPRSR
    CEXRCDUT CEXTECL
    

Fix information

  • Fixed component name

    IMS CONNECT EXT

  • Fixed component ID

    5655K4800

Applicable component levels

  • R220 PSY UK56413

       UP10/05/01 P F004

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88S","label":"IMS Connect Extensions"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0"}]

Document Information

Modified date:
22 October 2020