Error description

  • In a TWSz environment with high workstation analyzer ( WSA )
    actitivty it is possible for the long duration message
    ( EQQE038I ) to be issued incorrectly in the case where both
    actual duration and estimated duration are less than one
    minute, and actual duration is not greater than:
    (1) estimated duration * ALEACTION
    or
    (2) esimtated duration * LIMFDBK
    depending on whether ALEACTION and LIMFDBK are specified.
    The ALEACTION value overrides the LIMFDBK value if both
    parameters are specified.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All TWS for z/OS 8.3.0, 8.5.0 and 8.5.1      *
    *                 users.                                       *
    *                 FUNCTION=WA                                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: The EQQE038I message can be wrongly     *
    *                      issued for jobs having a duration less  *
    *                      than 1 minute.                          *
    ****************************************************************
    * RECOMMENDATION: APPLY THE PTF FIXING THIS APAR               *
    ****************************************************************
    In the Workstation Analyzer a bad comparison could happens
    between the Max duration field stored in DOA area and the job
    duration that it is calculated at run time when the Actual
    duration and the Planned duration are under 1 minute and the
    Actual duration value exceeds the product between Planned
    duration and ALEACTION or LIMFDBK parameter.
    The issue there is because the filed stored in DOA it is in
    hundredth of seconds and the Actual Duration calculated at run
    time it is in thousandth of seconds.
    
    Besides the scenario above another fix has been done for the
    FTA job under 1 minute, for this jobs the Actual duration
    it is always equal to a minute, it means that the LONG DURATION
    message could be issued in unpredictable way, for this reason
    the LONG DURATION message will be always inhibit when the job
    runs on FTA ws and the duration it is under 1 minute.
    

Problem conclusion

  • The comparison between the Max duration stored in DOA and s in
    the Duration calculated at run time has been fixed.
    Inhibited the LONG DURATION message when the job it is under
    1 minute and the job runs on FTA ws.
    302Y
    502Y
    512Y
    EQQWALTE
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM07923

  • Reported component name

    TIV WRKLD SCHD

  • Reported component ID

    5697WSZ01

  • Reported release

    300

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2010-02-18

  • Closed date

    2010-04-23

  • Last modified date

    2010-06-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK56365 UK56366 UK56367

Modules/Macros

  • EQQWALTE
    

Fix information

  • Fixed component name

    TIV WRKLD SCHD

  • Fixed component ID

    5697WSZ01

Applicable component levels

  • R302 PSY UK56365

       UP10/05/28 P F005

  • R502 PSY UK56366

       UP10/05/28 P F005

  • R512 PSY UK56367

       UP10/05/28 P F005

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSRULV","label":"IBM Workload Scheduler for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"300","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"300","Edition":"","Line of Business":{"code":"","label":""}}]