Error description
incorrect GetPage Per Read in All Threads Connected to DB2 workspace in ITM TEP.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - The component that transfers DB2 * * monitoring data collected by the * * OMEGAMON collector to the TEMA * * - Classic Interface * **************************************************************** * PROBLEM DESCRIPTION: INCORRECT "GETPAGE PER READ" VALUE * * IN ALL THREADS CONNECTED TO DB2 * * WORKSPACE IN TEP. * **************************************************************** * RECOMMENDATION: Apply this PTF * * * **************************************************************** PROBLEM SUMMARY: Incorrect GETPAGE count was used for the calculation of "Getpage Per Read" value in TEP. PROBLEM CONCLUSION: Use the correct GETPAGE count for the calculation of "Getpage Per Read" value in TEP.
Problem conclusion
Use the correct GETPAGE count for the calculation of "Getpage Per Read" value in TEP. KEYWORDS : GETPAGE TEP GETPAGE PER READ
Temporary fix
Comments
APAR Information
APAR number
PM06377
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
420
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-01-29
Closed date
2010-05-28
Last modified date
2010-07-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK57398 UK57399
Modules/Macros
KO2CT2SA KO2CT2SS KO2CT2S2
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]