IBM Support

PM06129: VARIOUS CORRECTIONS OF CUA PANELS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • 1)EDM graph on CUA panels KD2REDMD and KD2RHEDP displays
    incorrect colors when EDMU alert tripped.
    2)CUA ATF panels do not recognize that ATF commands are not
    supported for remote DB2.
    3)CUA panel KD2VITS2(Inactive threads by package) displays the
    data erroneously.
    4)Some exceptions (WSRV,WLGQ,WDLK,WCLM,WGLK,WSPS) do not pass
    the thresholds' values during logon to Classic session from CUA.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   CUA Interface                            *
    ****************************************************************
    * PROBLEM DESCRIPTION: VARIOUS CORRECTIONS OF CUA PANELS       *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    *                                                              *
    ****************************************************************
    PROBLEM SUMMARY:
    1.CUA ATF PANELS DO NOT RECOGNIZE THAT ATF COMMANDS ARE NOT
    SUPPORTED FOR REMOTE DB2.
    2.EDM GRAPH ON CUA PANELS KD2REDMD AND KD2RHEDP DISPLAYS
    INCORRECT COLORS WHEN EDMU ALERT TRIPPED.
    3.CUA PANEL KD2VITS2(INACTIVE THREADS BY PACKAGE) DISPLAYS DATA
    ERRONEOUSLY.
    4.CUA PANEL KD2ORCTD(CICS RCT SUMMARY) DOES NOT REQUEST '/' AND
    ACTION PULLDOWN MENU WORKS INCORRECTLY
    5.ACTION PULLDOWN MENU WORKS INCORRECTLY FOR OBJECT ANALYZER AND
    FOR EDM PANELS KD2RESCA, KD2RESCL, KD2RESCT IN CUA
    6.SOME EXCEPTIONS (WSRV,WLGQ,WDLK,WCLM,WGLK,WSPS) DO NOT PASS
    THE THRESHOLDS' VALUES TO CLASSIC DURING LOGON TO CLASSIC
    SESSION FROM CUA
    
    PROBLEM CONCLUSION:
    1.CHANGE CUA ATF PANELS TO RECOGNIZE REMOTE DB2.
    2.CORRECT CUA PANELS KD2REDMD AND KD2RHEDP TO DISPLAY EDM GRAPH
    WITH CORRECT COLORS.
    3.CHANGE LOGIC OF PANEL KD2VITS2 TO DISPLAY DATA CORRECTLY
    4.CORRECT THE PROCESSING OF ACTION PULLDOWN MENU ON PANEL
    KD2ORCTD
    5.CHANGE THE PROCESSING OF ACTION PULLDOWN MENU FOR OBJECT
    ANALYZER AND FOR EDM PANELS KD2RESCA, KD2RESCL, KD2RESCT IN CUA
    6.CORRECT PROCESSING OF WSRV,WLGQ,WDLK,WCLM,WGLK,WSPS
    EXCEPTIONS TO PASS THRESHOLDS' VALUES TO CLASSIC FROM CUA
    

Problem conclusion

  • 1.CHANGE CUA ATF PANELS TO RECOGNIZE REMOTE DB2.
    2.CORRECT CUA PANELS KD2REDMD AND KD2RHEDP TO DISPLAY EDM GRAPH
    WITH CORRECT COLORS.
    3.CHANGE LOGIC OF PANEL KD2VITS2 TO DISPLAY DATA CORRECTLY
    4.CORRECT THE PROCESSING OF ACTION PULLDOWN MENU ON PANEL
    KD2ORCTD
    5.CHANGE THE PROCESSING OF ACTION PULLDOWN MENU FOR OBJECT
    ANALYZER AND FOR EDM PANELS KD2RESCA, KD2RESCL, KD2RESCT IN CUA
    6.CORRECT PROCESSING OF WSRV,WLGQ,WDLK,WCLM,WGLK,WSPS
    EXCEPTIONS TO PASS THRESHOLDS' VALUES TO CLASSIC FROM CUA
    
    KEYWORDS : CUA PANELS PANEL
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM06129

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-01-27

  • Closed date

    2010-05-26

  • Last modified date

    2010-06-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK57235 UK57242

Modules/Macros

  • KD2$CEP2 KD2DATF1 KD2DATF2 KD2DATF3 KD2DATF4
    KD2ORCDD KD2ORCTD KD2PSARP KD2PSA3P KD2REDMD KD2RESCA KD2RESCD
    KD2RESCE KD2RESCL KD2RESCT KD2RHEPD KD2SPROF KD2SRPRO KD2VACTB
    KD2VITS2 KD2VTCAN KD2VTPSD KD20ACTB
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R410 PSY UK57235

       UP10/05/29 P F005

  • R420 PSY UK57242

       UP10/05/29 P F005

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
03 June 2010