IBM Support

PM05544: CQ 7.1.0 RCP Startup Queries do not run at login and decorations are missing.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ClearQuest 7.1.0 RCP Startup Queries do not run at login and dec
    orations are missing.
    
    After upgrading to 7.1.0.1/FL7 and 7.1.0.2/FL7 from 7.0.1/FL5, y
    ou are unable to get more than one startup query to work.  Addin
    g more than one startup query prevents any startup queries from
    running and causes the Startup Query decorations to be missing a
    fter re-login.
    

Local fix

Problem summary

  • When setting a query as a startup query, a calculation is
    performed to find the site_id, which is checked against the
    original site_id from the database.  The problem is that
    they do not always match based on some the query dbids.
    This calculation is obsolete and not needed because after it
    is done, a SQL select statement is performed to check
    whether the query dbid is in the table, which is as good of
    a check as it can get. We removed the obsolete method that
    does the calculation and the call to it, leaving just the
    select query check.  This change fixes the problem.
    

Problem conclusion

  • A fix is available in ClearQuest 7.0.0.9, 7.0.1.8, and
    7.1.1.1.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM05544

  • Reported component name

    CLEARQUEST WIN

  • Reported component ID

    5724G3600

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-01-19

  • Closed date

    2010-04-15

  • Last modified date

    2010-04-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CLEARQUEST WIN

  • Fixed component ID

    5724G3600

Applicable component levels

  • R710 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSSH5A","label":"Rational ClearQuest"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: