Error description
HPIC V4.1 terminates with ABEND 0C4 when HPIC is run by IMS compatible JCL with multiple steps HASH check.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Image Copy for z/OS * * Version 4 Release 1 users ( FMID=H1J0410 ) * **************************************************************** * PROBLEM DESCRIPTION: This APAR provides a fix for following * * problems of HP Image Copy. * * 1. ABEND S0C4 ( ABEND0C4 ) at FABJDMP9 * * occurs when HP Image Copy is run * * under IMS compatible JCL with * * Multiple steps HASH check. * * 2. DEDB Pointer Checker issues * * unnecessary report header reports * * for every area when HP Image Copy * * runs under IMS Fast Path Basic * * Tools. * * 3. ABEND S0C4 ( ABEND0C4 ) at FABJDPSB * * occurs when HP Image Copy uses * * DFSMSdss DUMP command and fails to * * open an empty DEDB. * * 4. ABEND U0999 ( ABENDU0999 ) at * * FABJMAIN occurs when HP Image Copy * * processes only DEDB with DBALL=Y and * * HP pointer checker library is * * specified in STEPLIB. * * 5. ABEND U3916 ( ABENDU3916 ) at * * FABJDPS7 occurs when HP Image Copy * * encounters an unrecoverable I/O * * error in an image copy data set for * * DEDB with HPIO=Y. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** This APAR provides a fix for following problems of HP Image Copy. 1. ABEND S0C4 ( ABEND0C4 ) at FABJDMP9 occurs when HP Image Copy is run under IMS compatible JCL with Multiple steps HASH check. 2. DEDB Pointer Checker issues unnecessary report header reports for every area when HP Image Copy runs under IMS Fast Path Basic Tools. 3. ABEND S0C4 ( ABEND0C4 ) at FABJDPSB occurs when HP Image Copy uses DFSMSdss DUMP command and fails to open an empty DEDB. 4. ABEND U0999 ( ABENDU0999 ) at FABJMAIN occurs when HP Image Copy processes only DEDB with DBALL=Y and HP pointer checker library is specified in STEPLIB. 5. ABEND U3916 ( ABENDU3916 ) at FABJDPS7 occurs when HP Image Copy encounters an unrecoverable I/O error in an image copy data set for DEDB with HPIO=Y. The causes of the problems are as follows: 1. HP Image Copy wrongly judges that the process is FASTIC because it uses nonexistent internal block under IMS compatible JCL. It is possible problem by storage condition. 2. HP Image Copy function that is invoked by IMS Fast Path Basic Tools has problems on following DD for the DEDB Pointer Checker. - MSGOUT DD - REPORTS DD If these DD are defined as the sequential data set (DSORG=PS), Hash check result reports only one area. If these DD are defined as the partitioned data set (DSORG=PO), the JOB terminates with ABEND S213-30 ( ABEND213 RSN30 ). If these DD are defined as the SYSOUT, unnecessary report header reports for every area. The cause of this problem is that DEDB Pointer Checker is called for initialization many times by HP Image Copy. 3. HP Image Copy does not clear the address of the freemained work area. 4. HP Image Copy creates a parameter list with no entries for HP Pointer Checker in the DBALL check routine. HP Pointer Checker judges it as a bad parameter list and returns error return code to HP Image Copy. 5. HP Image Copy unallocates an open ADS without closing.
Problem conclusion
FABJDMPN has been modified as follows: - Bypass FASTIC process under IMS compatible JCL. - Call the DEDB Pointer Checker with FUNC=INIT only once. FABJDBAL has been modified to return to FABJMAIN with RC=8 when it creates a parameter list with no entries for HP Pointer Checker. FABJMAIN has been modified as follows: - Change DBALL=Y to DBALL=N and bypass DBALL check routine when FABJDBAL returns with RC=8. - Change ABEND U0999 ( ABENDU0999 ) to ABEND U3999 ( ABENDU3999 ) because ABEND U0999 is test ABEND code. FABJDFCN has been modified not to call FABJMDPN when the address of the freemained work area is cleared. FABJMDPN has been modified to clear the address of the freemained work area. FABJDPSN has been modified to unallocate an open ADS after closing. The following modules have been reassembled. FABJDFCA FABJDFCB FABJDFC7 FABJDFC8 FABJDFC9 FABJDMPA FABJDMPB FABJDMP7 FABJDMP8 FABJDMP9 FABJDPSA FABJDPSB FABJDPS7 FABJDPS8 FABJDPS9 FABJMDPA FABJMDPB FABJMDP7 FABJMDP8 FABJMDP9
Temporary fix
Comments
APAR Information
APAR number
PM04416
Reported component name
IMS HP IMAGE CO
Reported component ID
5655K9600
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2010-01-05
Closed date
2010-01-19
Last modified date
2010-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK53654
Modules/Macros
FABJDBAL FABJDFCA FABJDFCB FABJDFCN FABJDFC7 FABJDFC8 FABJDFC9 FABJDMPA FABJDMPB FABJDMPN FABJDMP7 FABJDMP8 FABJDMP9 FABJDPSA FABJDPSB FABJDPSN FABJDPS7 FABJDPS8 FABJDPS9 FABJMAIN FABJMDPA FABJMDPB FABJMDPN FABJMDP7 FABJMDP8 FABJMDP9
Fix information
Fixed component name
IMS HP IMAGE CO
Fixed component ID
5655K9600
Applicable component levels
R410 PSY UK53654
UP10/01/26 P F001
Fix is available