A fix is available
APAR status
Closed as new function.
Error description
This APAR will address the following: - The CEX event trace records are limited to 1024 bytes Allow customer specification of the size of the CEX trace records using a new control input dataset with control cards to specify the size of the CEX trace records up to a limit of 7168 bytes. - Enable the CEX GUI to provide support for IMS OTMA supported commands Change the CEX GUI and suporting CEX console services to allow the GUI to submit IMS commands via IMS Connect. The class of IMS type 1 commands support are those commands that can be submitted from an OTMA client. - Provide a new feature in CEX to support the IMS Connect client sending data that is logged to the CEX journal as an client data event. - Provide support for a client to send client specific data to the CEX service exit, CEXSVC01. The data provided is recorded to the CEX journal. - Running the IMS Connect extension V2R2 utility CEXRTCNV to convert the RECORDER trace data into symbol length records in the format of IMS Connect Extensions event records, the OPB data of the ICONRC record is not converted. - Add a message number to the prefix of the following: CEX FAILED TO INITIALIZE, RSN=040D031B - SEE CEXPRINT * For information on using the new features provided with this APAR, search for Technote (FAQ) documents relating to PM04021 in the IMS Tools Support portal. http://www-947.ibm.com/support/entry/portal/Overview/Software/In formation_Management/IMS_Tools PTF UK54485 requires the following changes to allow SMP/E to process successfully: SMPPTS - Needs at least 215 CYL free space during the SMP/E RECEIVE process. SYSUT1 - Needs at least 350 Cyl as primary space with 200 cyl secondary during the SMP/E APPLY process. SMPWRK6 - Needs at least 350 Cyl as primary space with 200 cyl secondary during the SMP/E APPLY process.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Connect Extentions V2.2 * **************************************************************** * PROBLEM DESCRIPTION: This APAR is making various * * improvements to CEX V2.2 * **************************************************************** * RECOMMENDATION: * **************************************************************** This APAR will address the following: 1. The CEX event trace records are limited to 1024 bytes. 2. Enable the CEX GUI to provide support for IMS OTMA supported commands. 3. Provide a new feature in CEX to support the IMS Connect client sending data that is logged to the CEX journal as an client data event. 4. OPB formatting error in Recorder Trace Conversion utility. 5. Message CEX FAILED TO INITIALIZE, RSN=040D031B - SEE CEXPRINT does not contain message number.
Problem conclusion
Temporary fix
Comments
The following changes have been made for the above: 1. Allow customer specification of the size of the CEX trace records using a new control input dataset with control cards to specify the size of the CEX trace records up to a limit of 7168 bytes. 2. Change the CEX GUI and suporting CEX console services to allow the GUI to submit IMS commands via IMS Connect. The class of IMS type 1 commands support are those commands that can be submitted from and OTMA client. 3. Provide support for a client to send client specific data to the CEX service exit, CEXSVC01. The data provided is recorded to the CEX journal. 4. Correct OPB formatting error in Recorder Trace Conversion utility. 5. Change message to CEX5006E CEX FAILED TO INITIALIZE, RSN=040D031B - SEE CEXPRINT
APAR Information
APAR number
PM04021
Reported component name
IMS CONNECT EXT
Reported component ID
5655K4800
Reported release
220
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function
Submitted date
2009-12-21
Closed date
2010-02-18
Last modified date
2010-03-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK54485
Modules/Macros
CEX#OPA0 CEX#PRIM CEX#SHCS CEX#SHEL CEX#SHSP CEX#SHTS CEXACL10 CEXCERE CEXCONSC CEXCPSR CEXEVTPR CEXEVT01 CEXEVWTR CEXFUNCM CEXGUIW CEXMAIN CEXMSGCM CEXMSGL CEXMSGT CEXM03 CEXOPAP0 CEXOPDRV CEXPRED0 CEXPRED1 CEXRCDUT CEXREAD CEXR171 CEXSHCSP CEXSHELL CEXSHELP CEXSHSPP CEXSMAP6 CEXSVCCB CEXSVC01 CEXTECL CEXTEOT CEXTPXML H28S220J
Fix information
Fixed component name
IMS CONNECT EXT
Fixed component ID
5655K4800
Applicable component levels
R220 PSY UK54485
UP10/02/23 P F002
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88S","label":"IMS Connect Extensions"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0"}]
Document Information
Modified date: