APAR status
Closed as program error.
Error description
The Composite Application REST service allows to order applications by their size. The comparison calculation was not implemented correctly which resulted in an incorrect order of the applications.
Local fix
Problem summary
For the creator of an application only the ObjectID was stored and not the DN. Furthermore a possible unique name for a template was not stored, resulting in staging problems as the the ObjectIDs of template are likely to differ between systems.
Problem conclusion
The DN of the creator and the unique name of the template, if set, is stored now. During restore the code will first check if a template with the specified ObjectID is available. If not it checks if a template with the specified unique name, if contained in the backup file, is available. Manuel Steps: None Failing Module(s): Composite Applications Affected Users: All users Version Information: Portal Version(s): 6103, 6150 Platform Specific: This fix applies to all platforms. PM02211 is part of Cumulative Fix 01 for Portal 6.1.5. The fix is available from Fix Central: http://www.ibm.com/eserver/support/fixes/fixcentral/swgquickorde r?apar=PM02238&productid=WebSphere%20Portal&brandid=5 You may need to type or paste the complete address into your Web browser.
Temporary fix
Comments
APAR Information
APAR number
PM02211
Reported component name
WEBSPHERE PORTA
Reported component ID
5724E7600
Reported release
615
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-11-30
Closed date
2010-02-16
Last modified date
2010-02-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBSPHERE PORTA
Fixed component ID
5724E7600
Applicable component levels
R615 PSY
UP