IMS Hardware Data Compression Extended Support for IMS V11. KEYWORDS: IMSV11TGT/K
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: IMS V11 users of the tool's ISPF Dialog. * **************************************************************** * PROBLEM DESCRIPTION: IMS V11 data entry value "11" not * * recognized. * **************************************************************** * RECOMMENDATION: * **************************************************************** IMS V11 validation logic missing on panel HCOP12.
Problem conclusion
Temporary fix
Comments
IMS V11 validation logic added to panel HCOP12.
APAR Information
APAR number
PM01927
Reported component name
IMS HDCE
Reported component ID
5655E0200
Reported release
220
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2009-11-23
Closed date
2009-11-23
Last modified date
2010-08-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK52221
Modules/Macros
HCOP12
Fix information
Fixed component name
IMS HDCE
Fixed component ID
5655E0200
Applicable component levels
R220 PSY UK52221
UP09/11/25 P F911