A fix is available
APAR status
Closed as program error.
Error description
- Cleanup not working during signoff. - Abend S0C4 (abend0c4) in ETO Support signoff cleanup routine (IZTCLNA7,IZTCLNA8,IZTCLNA9,IZTCLNAA,IZTCLNAB). The abend occurs on instruction: X'D507 F014 CF22' CLC 20(8,R15),XF22'(R12) A temporary workaround could be to turn off signoff cleanup. - Incorrect value displayed on IZTRAN "SLU2 TRANSLATION LOOKUP" field "BYP DEQ" when an LU name record requests that messages not be dequeued.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS ETO Support V3.1 * **************************************************************** * PROBLEM DESCRIPTION: Cleanup not working during signoff. * **************************************************************** * RECOMMENDATION: * **************************************************************** This APAR is correcting the following problems: 1.Abend S0C4 (abend0c4) in ETO Support signoff cleanup routine (IZTCLNA7,IZTCLNA8,IZTCLNA9,IZTCLNAA,IZTCLNAB). The abend occurs on instruction: X'D507 F014 CF22' CLC 20(8,R15),XF22'(R12) A temporary workaround could be to turn off signoff cleanup. 2.Incorrect value displayed on IZTRAN "SLU2 TRANSLATION LOOKUP" field "BYP DEQ" when an LU name record requests that messages not be dequeued.
Problem conclusion
Code has been modified to correct the above problems.
Temporary fix
Comments
ž**** PE10/03/02 FIX IN ERROR. SEE APAR PM08784 FOR DESCRIPTION
APAR Information
APAR number
PM00734
Reported component name
IMS ETO SUPPORT
Reported component ID
5655E1200
Reported release
310
Status
CLOSED PER
PE
YesPE
HIPER
YesHIPER
Special Attention
NoSpecatt
Submitted date
2009-11-06
Closed date
2009-11-20
Last modified date
2010-03-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK52181
Modules/Macros
IZTCLNAA IZTCLNAB IZTCLNA7 IZTCLNA8 IZTCLNA9 IZTLKUP0 IZTSGFXA IZTSGFXB IZTSGFX7 IZTSGFX8 IZTSGFX9
Fix information
Fixed component name
IMS ETO SUPPORT
Fixed component ID
5655E1200
Applicable component levels
R310 PSY UK52181
UP09/11/21 P F911 ®
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX897","label":"IMS ETO Support"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
29 March 2010