APAR status
Closed as program error.
Error description
IBM Legcy API PortletContext.sendMessage() fails on Portal 6.1
Local fix
Problem summary
Legacy Portlet Messaging does not work if the Abstract Portlet name is passed in the send() call. In Portal 5.1 the same call sent the message to all Portlets on a page that are children of the abstract portlet.
Problem conclusion
This fix enables our customer to define alias names for the receiving portlet. This makes it possible to configure this alias in a way that re-enables the pre-6.1 behaviour. To enable the alias feature the following property has to be set for WP ConfigService: legacy.portlet.messaging.enable.alias=true For a specific Portlet that should have an abstract name alias the following Config-Parameter has to be set in portlet.xml or the Admin-Console of Portal: com.ibm.wps.pe.pc.legacy.messaging.alias=<alias-name> After that configuration, a send() call with the <alias-name> as portletName parameter will dispatch the message additionally to all portlets on the page that have this alias. Manual Steps: None Failing Module(s): Portlet Container Affected Users: All Users Version Information: Portal Version(s): 6.1.0.1 Pre-Requisite(s): Co-Requisite(s): --- Portal Version(s): 6.1.0.2 Pre-Requisite(s): Co-Requisite(s): --- Platform Specific: This fix applies to all platforms. A fix is available from Fix Central: http://www.ibm.com/eserver/support/fixes/fixcentral/swgquickorde r?apar=PM00184&productid=WebSphere%20Portal&brandid=5 You may need to type or paste the complete address into your Web browser.
Temporary fix
Comments
APAR Information
APAR number
PM00184
Reported component name
WEBSPHERE PORTA
Reported component ID
5724E7600
Reported release
61B
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-11-03
Closed date
2009-11-18
Last modified date
2009-11-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBSPHERE PORTA
Fixed component ID
5724E7600
Applicable component levels
R61A PSY
UP
R61B PSY
UP