The customer will see Serialization exceptions when scheduled actions are triggered like expiring, etc. In the SystemOut.log, you will see errors like the following: 00001cf4 EJBSchedulerB I implode() - returning null IOException java.io.InvalidClassException: com.aptrix.pluto.content.Content; local class incompatible: stream classdesc serialVersionUID = -1089925949120930392, local class serialVersionUID = -8553745472525354033 00001cf4 EJBSchedulerB W ejbTimeout() - Schedulable when the scheduled actions are supposed to triggered.
Local fix
Problem summary
SERIALIZATION EXCEPTIONS WHEN SCHEDULED ACTIONS ARE TRIGGERED
Problem conclusion
Problem Solution: WCM changed to not serialize the Class, so that when the action is triggered, the Class will not need to be deserialized. Also, in order to address the issue with items that are already scheduled, a Module needs to be run that will reschedule all pending tasks. In order to do so, the instructions are: * Update the WCMConfigService.properties. Add the following: to connect.businesslogic.module=, add at the end ,workflowcontrolchecker * Add the following to the list of modules connect.businesslogic.module.workflowcontrolchecker.class= com.aptrix.pluto.workflow.WorkflowControlCheckerModule connect.businesslogic.module.workflowcontrolchecker.remoteaccess =true connect.businesslogic.module.workflowcontrolchecker.autoload=fal se That can be injected after the memberfixer module section for example. * Restart server * Run on URL http://host:port/wps/wcm/myconnect?MOD=WorkflowControlChecker&li brary=libraryName That will run in report mode. Adding &fix=true will save the items in the repository.
Temporary fix
Comments
APAR Information
APAR number
PM00121
Reported component name
LOTUS WEB CONT
Reported component ID
5724I2901
Reported release
60K
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-10-30
Closed date
2009-11-10
Last modified date
2009-11-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
LOTUS WEB CONT
Fixed component ID
5724I2901
Applicable component levels
R60K PSY
UP
R61A PSY
UP
R61B PSY
UP
R61C PSY
UP
[{"Business Unit":{"code":"BU051","label":"N\/A"},"Product":{"code":"SUPPORT","label":"IBM Web Content Manager"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.1.6","Line of Business":{"code":"LOB33","label":"N\/A"}}]
Document Information
Modified date:
21 December 2021