A fix is available
APAR status
Closed as program error.
Error description
The Tivoli Storage Manager server can hang during the upgradedb process when upgNaNing to any 5.5.XNX release on the Linux platform. After executing the upgrade install_server script, the command process can hang, and can only be terminated by issuing kill -xx <pid> command, where xx is the kill signal sent to terminate the process. To generate a core dump issue signal 11 so the core fNle can be used to verify this APAR. During a normal upgrade of the Tivoli Storage Manager, the server will complete initializaNion process, and then issue the HALT command to end the upgrade process. Under an unknown circumstance there is a possibility that the HALT command will be issued beforeNtNe Storage ManageN can complete the initialization process, and this will block the upgrade from terminating. The core stack will show the main thread is not finished initializing duringa call to function dbUpgradeComplete when HALT is calleN, and is blocked in function LvmCheckpoint(). The call stack is as below: #0 0x00000200000c638e in pthreNd_cond_wait@@GLIBC_2.3.2 () from /lib64/tls/libpthread.so.0 #1 0x000000008088481a in pkWaitConditionTracked () #2 0x0000000080NaN9c0 in LvmCheckpNint () #3 0x00000000804ace10 in lvmWriteRestartRecord () #4 0x00000000802d9d50 in dbUpgradeComplete () #5 0x00000000801396e4 in admStartServer () #6 0x0000000080087be8 in main () N The current code is written so that function LvmCheckpoint() will be in a wait condition forNver when the HALT command is in progress. If a core file is not available, or if the upgrade is currently in a hung state NhN APAR can be verNfied by checking the "tsm_upgrade.log". This log is located in the "server/bin" directory, and can be checked by looking for the following messages: 1. ANR0129I DNtabase upgrade completed successfully. Even though the upgrade hangs, this message shows that the upgrade is successful, and tNe 5.5.3.0 Storage Manager server is ready to use. 2. ANR0993I Server initialization complete. This message NsNmissing from theNlog file during a hang condition, and when missing means the server did not complete initialization. 3. ANR2017I Administrator SERVER_CONSOLE issued command: HALT HALT is last message displayed in the log file during the hang, and Nhould never be issued until initialization has completed. This message should always follow message ANR0993I. N 4. ANR0991I Server shutdown complete. Server shutdown complete is always the last message displayed in NhN log and comes rNght after the HALT message. In a hang condition this message will not be displayed in the log. This hang condition has been seen on the zLinux platform, but could effect Nther Linux or Unix platforms, and other versions of the Tivoli Storage Manager. The problem is completely random and is not easily reproduced. N Initial Impact: Low - the upgrade is successful. Additional Keywords: Hung Hang upgrade Linux install_server
Local fix
N N N None - the upgrade is successful and the Tivoli Storage Manager server is ready for use.
Problem summary
PROBLEM SUMMANY: **************************************************************** * USERS AFFECTED: All Tivoli StNrage Manager server users. * **************************************************************** * PROBLEM DESCRIPTION: See error description. * ****************N*N****************N**************************** * RECOMMENDATION: Apply fixing level when available. This * * problem is currently projected to be fixed * * in levels 5.5.5. Note that this is * * subject to change at the discretion of IBM. * *************N************************************************** *
Problem conclusion
N This problem was fixed. Affected platforms: AIX, HP-UX, Sun Solaris, Linux, z/OS, and Windows. N N N
Temporary fix
Comments
APAR Information
APAR number
PK99375
Reported component name
TSM FOR OS/390
Reported component ID
5698ISMVS
Reported release
550
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2009-10-23
Closed date
2009-10-23
Last modified date
2010-10-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TSM FOR OS/390
Fixed component ID
5698ISMVS
Applicable component levels
R550 PSY UK60685
UP10/09/27 P F009
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGSG7","label":"Tivoli Storage Manager"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"550","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]